> ## Documentation Index
> Fetch the complete documentation index at: https://docs.megaport.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Planning Your Deciso OPNsense Deployment

> This help topic describes Deciso OPNsense deployment considerations for the Megaport Virtual Edge (MVE).

This topic provides an overview of the provisioning process and describes deployment considerations for the Megaport Virtual Edge (MVE).

| **You Provide** | **Megaport Provides** |
| - | - |
| Internet connection from branch | Platform to host the OPNsense virtual appliance |
| OPNsense enabled at branch | Complete connection from a branch to any destination on the Megaport network and interoperation with other Megaport products and services |
| Customer premises equipment (CPE) installed in branch | Megaport Internet connection to terminate the tunnel between MVE and CPE at branch via internet |
| OPNsense license (if using Business Edition) to use on Megaport SDN | Access to the Megaport ecosystem |

## Deployment considerations

This section describes MVE deployment options and sizing for Deciso OPNsense. For an overview of OPNsense features, see [Deciso OPNsense with Megaport Virtual Edge](https://docs.megaport.com/mve/deciso.md). For information about all supported NFVs Glossary NFVs Network Function Virtualization (NFV) is a network architecture approach that virtualizes network service such as firewalls, routers, load balancers, and VPNs, which are traditionally run on proprietary hardware. These services are deployed as software-based functions on standard, commodity hardware, allowing for greater flexibility, scalability, and cost efficiency. on the MVE platform, see the [Megaport Virtual Edge (MVE) product page](https://www.megaport.com/products/megaport-virtual-edge/).

### MVE locations

For a list of global locations where you can connect to an MVE, see [Megaport Virtual Edge Locations](https://docs.megaport.com/mve/locations.md).

**size**

### Sizing your MVE instance

The instance size determines the MVE capabilities, such as how many concurrent connections it can support. To size your MVE correctly, consult the vendor's sizing documentation to ensure it aligns with the number and type of features you plan to enable.

When choosing an MVE instance size, keep in mind these items:

* Any increase on the network data stream load can degrade performance. For example, establishing secure tunnels with IPsec, adding traffic path steering, or using deep packet inspection (DPI) can affect the maximum throughput speed.

* Future plans to scale the network.

To check which MVE instance sizes are available for your deployment, use the **MVE Size** section of the Create Virtual Edge page in the Megaport Portal. Instance size availability depends on both the selected vendor and the deployment location, and might vary accordingly. Only sizes supported by the selected vendor are listed, and sizes that are not available at the selected location are labeled *Not available here*.

**To check the MVE instance sizes in the Megaport Portal**

1. In the [Megaport Portal](https://portal.megaport.com), go to the **Services** page.

2. Click **Add Service**, then select **Virtual Edge (MVE)**.

   ![Add Service button](https://docs.megaport.com/images/snippets/add-services-button.png)

   The Create Virtual Edge page opens.

3. In the **Select Vendor / Product** section, select Deciso OPNsense.

4. In the **Location** section, select an MVE location.\
   Select a location geographically close to your target branch or on-premises locations. Use the **Search** field to find a location by metro or country name. Alternatively, browse the region tabs, then select a location.

   Size availability can differ between data centers at the same location. To check a specific data center, select Manual mode, then select the provider and data center.

5. View the available sizes in the **MVE Size** section.\
   Each size shows its vCPU and RAM allocation. Only sizes supported by the selected product are listed, and sizes that are not available at the selected location are grayed out and labeled *Not available here*. The sizes support varying numbers of concurrent connections, and individual partner product metrics vary slightly.

   ![MVE Size section showing the available sizes, with one size grayed out and labeled Not available here](https://docs.megaport.com/images/mve/create-mve-size.png)

   > [!NOTE]
   >
   > If the MVE size you want is not available, there is not enough capacity at the selected location. You can either select another location with enough capacity or contact your Account Manager to discuss requirements.

**What if I need more MVE capacity in the future?**

To increase your MVE capacity, you have these options:

* You can provision another MVE instance, add it to your network, and split the workload between the two MVEs.

* You can provision a larger MVE instance, migrate connections from the old MVE to the new larger MVE, and then retire the old MVE.

You can adjust the Megaport Internet bandwidth at any time without having to tear down the virtual machine.

### Security

MVE provides secure capacity to and from your internet-enabled branch locations, to any endpoint or service provider on the Megaport SDN.

### Licensing

Before you create an MVE in the Megaport Portal, you need user accounts with ordering permissions that provide access to the Megaport Portal. For more information, see [Creating an Account](https://docs.megaport.com/setting-up/registering.md).

OPNsense is open-source software. Deciso offers optional commercial support subscriptions and the OPNsense Business Edition with additional features and support. For more information, see the [Deciso website](https://www.deciso.com/).

### VLAN tagging

Megaport uses Q-in-Q Glossary Q-in-Q 802.1Q tunneling (also known as Q-in-Q or 802.1ad) is a technique used by OSI Layer 2 providers for customers. 802.1ad provides for both an *inner* and an *outer* tag whereby the outer (sometimes called S-tag for service provider) can be removed to expose the inner (C-tag or customer) tags that segment the data. to differentiate VXCs and MVEs on a host hardware system. The tenant MVE receives untagged traffic for the internet-facing link, and single-tagged 802.1Q traffic for VXCs toward other destinations on the Megaport network (such as CSP on-ramps or other MVEs). For more information, see [Configuring Q-in-Q](https://docs.megaport.com/connections/q-in-q.md).

### vNICs

Each MVE can have up to five vNICs. A Deciso OPNsense MVE is created with two vNICs by default:

* 0: WAN
* 1: LAN

You can add up to three more, making a total of five.

Before specifying the number of vNICs on your MVE:

* You cannot change the number of vNICs after ordering an MVE. Decide in advance how many vNICs to specify when you create the MVE.

* Consult your service provider to verify that adding a vNIC does not affect functionality.

> [!NOTE]
>
> If you need to change the number of vNICs after an MVE has been ordered, you must cancel and re-order the MVE.

For more information, see [Types of vNIC Connections](https://docs.megaport.com/mve/vnic-connections.md).


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.