# MCR Cloud Connectivity Overview Source: https://docs.megaport.com/cloud/mcr/index This help topic provides an overview of MCR cloud connectivity. Megaport Cloud Router (MCR) provides virtual routing capabilities for on-demand private connectivity at Layer 3. MCR is preconfigured in data centers in key routing zones around the world, enabling data transfer between: * Multicloud and hybrid cloud environments * Network service providers * Cloud service providers Without physical infrastructure, you can use cloud-to-cloud networking, private peering between leading public cloud, and providers, and direct connectivity to any provider on the Megaport software-defined network (SDN). There is no need to own and maintain equipment and no IP address or autonomous system numbers to procure. Click a Cloud Service Provider link in the site navigation to get started. For more information about MCR, see [MCR Overview](/mcr). ## Using a service key You can create a service key that allows you to share your service with another Megaport account holder. For more information, see [Setting up Service Keys](/marketplace/service-keys/). # MVE Cloud Connectivity Overview Source: https://docs.megaport.com/cloud/mve/index This help topic provides an overview of MVE cloud connectivity. Megaport’s ecosystem provides cloud on-ramps from leading cloud providers and you can instantly provision connectivity between your Megaport Virtual Edge (MVE) and a collection of leading cloud service providers (CSPs). Connectivity models vary by CSP. Click a CSP link for an SD-WAN provider in the site navigation to get started. For more information about MVE, see [MVE Overview](/mve). # Common Connectivity Scenarios Source: https://docs.megaport.com/connections/common-scenarios This help topic describes common connectivity scenarios when using Megaport. This topic describes eight common scenarios delivering different levels of protection at the physical layer connecting to Megaport SDN. Customer edge device stack (switch/router/firewall) at a single Megaport Point of Presence (PoP) with a single cross connect connecting to a single Port. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | N/A | | Switch Chassis | N/A | | SFP Transceiver | N/A | | Cross Connect | N/A | Scenario 1 Customer edge device stack (switch/router/firewall) at a single Megaport Point of Presence (PoP) with dual cross connects connecting to two Ports in a LAG. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | N/A | | Switch Chassis | N/A | | SFP Transceiver | 1 | | Cross Connect | 1 | Scenario 2 Customer edge device stack (switch/router/firewall) at a single Megaport Point of Presence (PoP) with dual cross connects connecting to two Ports not in a LAG on different chassis. You will need to discuss this option with your Sales Directors or Solutions Architect on the specific PoP location. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | N/A | | Switch Chassis | 1 | | SFP Transceiver | 1 | | Cross Connect | 1 | Scenario 3 Customer edge device stack (switch/router/firewall) at a single Megaport Point of Presence (PoP) with one cross connect connecting to one Port and one DC Interconnect (Campus) cross connect connecting to one Port at a different nearby Megaport PoP. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | N/A | | Switch Chassis | 1 | | SFP Transceiver | 1 | | Cross Connect | 1 | Scenario 4 Customer edge device (switch/router/firewall) at each of two Megaport PoPs with a single cross connect connecting to a single Port and with a separate connection between the two sites. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport Point of Presence (PoP) | 1 | | Switch Chassis | 1 | | SFP Transceiver | 1 | | Cross Connect | 1 | Scenario 5 Customer edge device stack (switch/router/firewall) at a single Megaport Point of Presence (PoP) with dual cross connects connecting to two Ports in a LAG and another dual DC Interconnect (Campus) cross connects to two Ports in a LAG at a different Megaport PoP. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | N/A | | Switch Chassis | 1 | | SFP Transceiver | 3 | | Cross Connect | 3 | Scenario 6 Customer edge device stack (switch/router/firewall) at each of two Megaport Points of Presence (PoPs) with dual cross connects connecting to two Ports in a LAG, and with a separate connection between the two sites. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | 1 | | Switch Chassis | 1 | | SFP Transceiver | 3 | | Cross Connect | 3 | Scenario 7 Customer edge device stack (switch/router/firewall) at each of two Megaport PoPs with dual cross connects connecting to two Ports not in a LAG on separate chassis, and with an optional separate connection between the two sites. You will need to discuss this option with your Sales Directors or Solutions Architect on the specific Point of Presence (PoP) location. **Protection at the Physical Layer** | Component | Protection | | - | - | | Megaport PoP | 1 | | Switch Chassis | Up to 3 (With separate connection between two sites) | | SFP Transceiver | 3 | | Cross Connect | 3 | Scenario 8 # Creating a Port Source: https://docs.megaport.com/connections/creating-port This help topic describes how to create a Port in the Megaport network. This topic describes how to create a in the Megaport network. Your organization’s Port is the physical point of connection between your organization’s network and the Megaport network. You need to deploy a Port wherever you want to direct traffic. The Megaport Portal presents the Port details, location, provider, configuration, and pricing options on a single page, with a live order summary that updates as you make selections. You can start with a single data center. For redundancy, we recommend selecting two different locations. Before proceeding, ensure that you have set up your Megaport Portal account. For more information, see [Setting Up a Megaport Account](/setting-up). **To create a new Port** 1. In the Megaport Portal, go to the **Services** page. 2. Click **Add Services**, then select **Port**. Add Services button The Create Port page opens. Complete the sections on this page to configure your Port. The order summary updates as you make selections. On wider screens, the summary is displayed in a panel on the right. On narrower screens, it is displayed in a bar at the bottom of the page that you can expand. Create Port page showing the Details and Location sections, with the order summary panel on the right 3. In the **Details** section, specify these fields: * **Port Name** -- Specify a name that helps you identify the Port, particularly if you plan to have more than one Port. * **Service Level Reference** (optional) -- Specify a unique identifying number for your Megaport service to be used for billing purposes, such as a cost center number, unique customer ID, or purchase order number. The service level reference number appears for each service under the Product section of the invoice. You can also edit this field for an existing service. A VXC associated with the Port is not automatically updated with the Port service level reference number. 4. In the **Location** section, select your preferred data center location.\ Use the **Search** field to find a location by metro name, country, data center name, or provider name. You can also search by address details, such as a street, city, state, or postcode. Alternatively, browse the region tabs, then select a location. 5. In the **Provider** section, select a data center provider, then select a data center from the drop-down list.\ Only providers and data centers available at your selected location are listed. If your search term in the Location section matches a specific provider or data center, the Provider list narrows to that provider. If the term matches only a metro or country, the Provider list shows every provider available at that location. Create Port page showing the Provider and Configuration sections 6. In the **Configuration** section, specify these fields: * **Port Speed** -- Select the required Port speed. Port capacity depends on location and service availability. Ensure that your equipment is capable of interfacing with the selected speed. * **Port Diversity** -- If diversity is available at your selected location and speed, a **Diversity Option** drop-down list appears. You can create two diverse Ports or choose an existing Port for the new Port to be diverse from. For more information about configuring Port diversity, see [Port Diversity](/connections/port-diversity). * **LACP & LAG Ports** -- To enable LACP, the Port speed must be 10 Gbps or higher. Enable LACP on Port if you want the Port to be a member of a LAG, then select the number of Ports in the LAG, up to a maximum of 8. For more information about LAG, see [Creating a Link Aggregation Group](/connections/lag). 7. In the **Pricing** section, specify these fields: * **Contract Term** -- Select a contract term. Longer terms result in a lower monthly rate. *12 Months* is selected by default. * **Contract Renewal** -- Automatically renews the contract at the same price and term length when the current term ends. This is enabled by default. If you disable it, the contract rolls over to a month-to-month term at the end of the current term, without the term discount. For more information, see [Minimum Term Renewal](/portal-admin/auto-renew). 8. In the **Add-ons** section, review the following: * **Cross Connect** -- If the location has Cross Connect availability, a option appears in the Add-ons section. Enable the **Cross Connect** add-on to add a Cross Connect to your Port order. The monthly rate and one-time fee for the Cross Connect appear on the card. For more information, see [Ordering a Cross Connect](/connections/cross-connect/). 9. In the **Resource Tags** section, add any tags you want to apply to this Port. * **Resource Tags** -- You can use resource tags to add your own reference metadata to a Megaport service.\ To add a tag: 1. Click **Add Tags**. 2. Click **Add New Tag**. 3. Enter details into the fields: * **Key** -- String, maximum length 128 characters. Valid values are a-z 0-9 \_ : . / \ - * **Value** -- String, maximum length 256 characters. Valid values are a-z A-Z 0-9 \_ : . @ / + \ - (space) 4. Click **Save**. If you already have resource tags for that service, you can manage them by clicking **Manage Tags**. Never include sensitive information in a resource tag. Sensitive information includes commands that return existing tag definitions and information that will identify a person or company. The price updates dynamically based on your selections in the order summary. Note that some partner-managed accounts do not display the pricing details. 10. Review the order summary, then click **Add Port**. Order summary panel showing the Port configuration, pricing, and the Add Port button The newly created Port is added to your cart, ready for checkout. If you create a service in a market that is not enabled, you are prompted to enable it first. For more information, see [Setting Up Financial Details](/setting-up/finance-basics). 11. Click **Review Order** to proceed through the checkout process, or click **Save** to save the configured services before placing the order. 12. Review the Important Information section and confirm agreement with the Service Agreements. If you do not have a promotion code, skip to the **Order Now** step. If you do have a promotion code, enter it into the **Enter discount code** field then click **Apply**. Alternatively, if a code already appears in the **Discounts** field, verify it is correct and click **Apply**. The promotional discount appears below the Standard Term discount. This discount is not reflected in the Monthly Rate shown here, it is applied at the time of billing. If an invalid or expired code causes an error with your order, contact your Megaport Account Manager for a replacement code. Add Promo Code If you entered an incorrect promotion code, you can remove it by clicking **Remove**. In addition to entering a promotion code manually, there are two other ways to apply promotion codes. * **Auto-apply** -- Megaport automatically applies the promotion code to your order. It appears automatically on the Checkout page. * **Manual list** -- Eligible promotion codes appear at checkout for any applicable services in your cart. You can then select and apply them. 13. Click **Order Now**. In most cases the Port is provisioned immediately, but sometimes it can take longer. After the Port is provisioned, Megaport generates a Letter of Authorization (LOA) specifying the demarcation point to be applied to your service. A PDF of the LOA is sent to you by email. 14. Click the **Download LOA** link next to the new Port on the Services page.\ The **Download LOA** link appears after the Port is available. For more information about the LOA, see [Megaport Letter of Authorization](/portal-admin/loa). 15. Provide the LOA to your data center operator to establish the physical Cross Connect from your network device to your new Port. The cost of a new cross connection and any related VXC fees are the responsibility of the customer, as outlined in [Megaport's Global Services Agreement](https://www.megaport.com/legal/global-services-agreement/). Once the Port has been provisioned and deployed, you have access to the Megaport network and can start adding Virtual Cross Connects (VXCs) to the Port. For more information about adding VXCs, see [Creating a VXC](/connections/overview#create_vxc). # Ordering a Cross Connect Source: https://docs.megaport.com/connections/cross-connect This help topic describes what a Cross Connect is and how to use it A Cross Connect is a dedicated physical point-to-point connection that links your location within a Megaport-enabled data center to a Megaport Port. It can only be ordered with a Port on a term. You can order a Cross Connect at the same time as you create your Port, after the Port order has been created but before the service is ordered, or after you have ordered the Port when it is in *Configured* status. If you order a Cross Connect at the same time as a Port, whichever method you used, Megaport will process the Cross Connect order with the data center to streamline the ordering process. When you order a Port with a Cross Connect, the Port will only be live after the Cross Connect has been deployed. This means that the Port will not be available within seconds, as it would be without the Cross Connect, but there will be a delay while the Cross Connect is provisioned. ## Ordering a Cross Connect when creating a Port You can order a Cross Connect during the Port creation process. **To order a Cross Connect when creating a Port** 1. Start the process to create a Port.\ For more information about creating a Port, see [Creating a Port](/connections/creating-port). 2. In the **Location** section, select the Port location. 3. In the **Details** section, specify a Port name, then in the **Configuration** section, select the Port speed.\ If the location has Cross Connect availability, a **Cross Connect** option appears in the **Add-ons** section, allowing you to include one with your Port order. Cross Connect card in the Add-ons section, with the toggle enabled 4. Enable the **Cross Connect** add-on to include a Cross Connect with your Port order.\ The pricing for the Cross Connect appears on the card. * **Monthly Rate** -- Displays the Cross Connect pricing in addition to the monthly Port fees. The term is the same as for the Port. * **One-Time Fee** -- Displays installation and decommissioning charges. If you include Link Aggregation Groups (LAGs) or Port diversity, incremental costs will be added to the Cross Connect on a per Port basis. For more information about LAGs, see [Creating a Link Aggregation Group](/connections/lag). For more information about Port diversity, see [Port Diversity](/connections/port-diversity). 5. Complete the remaining sections on the Create Port page.\ The order summary updates to include the Cross Connect monthly rate and one-time fee alongside the Port pricing. The term discount and any other associated discount apply only to the Port. 6. Click **Add Port**.\ The total monthly cost of the Port and Cross Connect is added to your cart. The one-time fee is not included in the cart total. 7. Click **Review Order**.\ The Cross Connect pricing is summarized.\ Read the Cross Connect disclaimer with the important information on the pop-up window. 8. Click **Order Now**. ## Ordering a Cross Connect after creating a Port, but before ordering the service If you decide you want to add a Cross Connect after creating your Port, you can add one before you click **Review Order** and deploy your service. **To order a Cross Connect before ordering the service** 1. Create a Port.\ For more information about creating a Port, see [Creating a Port](/connections/creating-port). 2. After clicking **Add Port** to finalize the Port setup, click the gear icon next to the connection on the Services page to make changes. How to edit a Port before it is ordered. If the location has Cross Connect availability, a **Cross Connect** option appears in the **Add-ons** section, allowing you to include one with your Port order. 3. Enable the **Cross Connect** add-on to add a Cross Connect to your order.\ The pricing for the Cross Connect appears on the card. * **Monthly Rate** -- Displays the Cross Connect pricing in addition to the monthly Port fees. The term is the same as for the Port. * **One-Time Fee** -- Displays installation and decommissioning charges. 4. Review the pricing information summary, then click **Update Port**. 5. Click **Review Order** and review the details. 6. Click **Order Now** to place your order. ## Ordering a Cross Connect when the Port is in Configured status If you decide you want to order a Cross Connect after you have created your Port, and clicked **Review Order** and **Order Now**, you can add a Cross Connect when it is in *Configured* status. **To order a Cross Connect in Configured status** 1. Go to the **Services** page. You will see the Port on the **Services** page in *Deployable* status while the Port is waiting for resource allocation. This image shows the Port entry on the Services page with the status as Deployable, and a message saying 'This Port is waiting for resource allocation'. After a few seconds, the status will change to *Configured*. This image shows the Port entry on the Services page with the status as Configured. 2. Click the gear icon next to the connection to make changes. How to edit a Port in configured status. If the location has Cross Connect availability, a **Cross Connect** section appears, allowing you to include one with your Port order. 3. Click **Yes** in the Cross Connect section to add a Cross Connect to your order. The Cross Connect will be added to your Port, and the pricing will be adjusted accordingly. The Port will remain in *Configured* status until the Cross Connect has been deployed. ## Uploading a Letter of Authorization (LOA) Megaport cannot deploy the Megaport-provisioned Cross Connect until you provide the . After you order the Cross Connect, you will receive an email from Megaport with a case reference number and instructions to complete your order. When the Port is in *Configured* status, an **Upload LOA** button appears on the Services page entry. Click it to open the Upload LOA screen, where you can upload a new LOA and view or download any LOA files already uploaded for the Cross Connect case. **To upload a LOA** 1. Click **Upload LOA** for the required Port on the Services page. 2. On the Upload LOA screen, drag and drop your LOA file onto the upload area, or click **browse to choose a file** and select it. The file must be a PDF and no larger than 5 MB. 3. Click **Upload LOA**. The uploaded file appears in the **Uploaded LOA file(s)** list. ### Viewing and downloading uploaded LOA files The Upload LOA screen lists any LOA files already uploaded for the Cross Connect case under **Uploaded LOA file(s)**, showing the name of each file and the date it was uploaded. To download a file, click **Download** next to it in the list. You cannot delete an uploaded LOA file. If you need to correct a mistake, upload a new file, and it will appear alongside the existing files in the list. ## Support Requests Portal Megaport creates a support case for each Cross Connect order. You can use the Support Requests Portal to see more details about your Cross Connect case and to keep track of progress.\ For more information, see [Support Requests Portal](/support/support-portal). You will be able to see these tabs: * **Activity** - The Activity tab allows you to see the activity that has taken place on the case. You can use this page to enter comments. Support Requests Portal activity tab * **Details** - In the Details tab, you can see the details of this Cross Connect order, including Port information and Cross Connect information. You can also add **Collaborators**, people in your organization that you want to participate in this case. Support Requests Portal details tab * **Attachments** - The Attachments tab is for uploading attachments, such as the LOA. Support Requests Portal Attachments tab For more information, see [Support Requests Portal](/support/support-portal). # Creating a Link Aggregation Group Source: https://docs.megaport.com/connections/lag This help topic describes how to work with Link Aggregation Groups within the Megaport network. This topic describes Port link aggregation groups (LAGs), steps through how to add a Port to a LAG, and how to convert a non-LAG Port to a LAG Port. A LAG bundles physical ports to create a single data path, where the traffic load is distributed among the ports to increase overall connection reliability. This feature provides aggregate bandwidth, enhanced resiliency, and efficient use of resources. Other terms used to describe a LAG include *port trunking*, *link bundling*, and *channel bonding*. When you create a new Port that is 10 Gbps or higher, enabling the allows you to use it in a LAG. We recommend that you enable LACP even if you only require a single Port at that time. This prevents service interruption if later you decide to enable LACP on the Port. You can combine up to 8 physical Ports into a single LAG, and the Port price will update dynamically based on any additional Ports. All Ports within the LAG use the same Layer 2 MAC address. For more information about how to create a Port, see [Creating a Port](/connections/creating-port). Multiple Ports in a LAG configuration with multiple physical cross-connects reduce potential single points of failure that will stop the network from working if they go down. For example, networks using small form-factor pluggable (SFP) ports or optics. This image shows the overall design of a LAG configuration: LAG configuration ## Port LAG specifications | **Specification** | **Port** | | - | - | | Protocol | LACP (IEEE 802.1AX or previous IEEE 802.3ad standards) | | Interface | 10GBASE-LR (10 Gbps) or 100GBASE-LR4 (100 Gbps) | | Maximum number of interfaces in a single LAG | 8 | ## Port LAG restrictions * Multi-Chassis Link Aggregation (MC-LAG) across multiple devices is not supported. * The LAG speed must be 10 Gbps or higher. 1 Gbps Ports are not supported in LAGs. * LACP System Priority must be set to a value higher than 0 on your equipment for LACP to function correctly. ### Bandwidth limitations The available total bandwidth of a LAG is the sum of all Ports in the LAG. Virtual Cross Connect (VXC) bandwidth is still limited to the maximum bandwidth of any single Port in the LAG. However, local Ports within the same metro area as Internet Exchange (IX) services don't have this limitation. You can configure IX services to use the total amount of bandwidth capacity from all members in a LAG. ## Configuring a LAG pair for diversity When you create a new LAG, you can make it diverse from an existing LAG or create a diverse pair of LAGs at the same time, with one in each diversity zone. For more information about Port diversity, see [Port Diversity](/connections/port-diversity). It is not possible to change a LAG diversity zone after placing the order. To do this, you must cancel and re-order the LAG. **To configure a LAG pair for diversity** 1. Log in to the Megaport Portal and choose **Services**. 2. Click **Add Services**, then select **Port**. Add Services button The Create Port page opens. Complete the sections on this page to configure your Port. The order summary updates as you make selections. On wider screens, the summary is displayed in a panel on the right. On narrower screens, it is displayed in a bar at the bottom of the page that you can expand. Create Port page showing the Details and Location sections, with the order summary panel on the right 3. In the **Details** section, specify a **Port Name**, then in the **Location** section, select a data center location for the Port.\ Use the **Search** field to find a location by metro name, country, data center name, or provider name. You can also search by address details, such as a street, city, state, or postcode. Alternatively, browse the region tabs, then select a location. 4. In the **Provider** section, select a data center provider and data center.\ Only providers and data centers available at your selected location are listed. If your search term in the Location section matches a specific provider or data center, the Provider list narrows to that provider. If the term matches only a metro or country, the Provider list shows every provider available at that location. 5. In the **Configuration** section, specify these fields: * **Port Speed** -- Select the required Port speed. Port capacity depends on location and service availability. Ensure that your equipment is capable of interfacing with the selected speed. If Port diversity is available at the location and speed you select, a **Diversity Option** drop-down list is enabled. If Port diversity is not available at your preferred location, contact a Megaport Sales representative for more information. * Configuration section showing the Diversity Option set to Create Diverse Pair, with the Second Port Name field * **LACP & LAG Ports** -- To enable LACP, the Port speed must be 10 Gbps or higher. Enable LACP on Port to add the Port as a member of a LAG, then select the number of Ports in the LAG, up to a maximum of 8. Configuration section showing 10 Gbps Port Speed selected, LACP enabled, and 4 ports in LAG 6. In the **Pricing** section, select a **Contract Term** and set **Contract Renewal**. For more information, see [Port Pricing and Contract Terms](/finance/port-pricing). 7. In the **Add-ons** section, review the following: * **Cross Connect** -- If the location has Cross Connect availability, a option appears in the Add-ons section. Enable the **Cross Connect** add-on to add a Cross Connect to your Port order. The monthly rate and one-time fee for the Cross Connect appear on the card. For more information, see [Ordering a Cross Connect](/connections/cross-connect/). 8. In the **Resource Tags** section, add any tags you want to apply. * **Resource Tags** -- You can use resource tags to add your own reference metadata to a Megaport service.\ To add a tag: 1. Click **Add Tags**. 2. Click **Add New Tag**. 3. Enter details into the fields: * **Key** -- String, maximum length 128 characters. Valid values are a-z 0-9 \_ : . / \ - * **Value** -- String, maximum length 256 characters. Valid values are a-z A-Z 0-9 \_ : . @ / + \ - (space) 4. Click **Save**. If you already have resource tags for that service, you can manage them by clicking **Manage Tags**. Never include sensitive information in a resource tag. Sensitive information includes commands that return existing tag definitions and information that will identify a person or company. 9. Review the order summary.\ The summary shows Port Diversity enabled and the diversity zones for the LAGs. The monthly charge includes both LAGs. If a Cross Connect has been ordered, the summary also shows the monthly rate and the one-time fee for the Cross Connect. 10. Click **Add Port**.\ The newly created LAGs, their diversity zones, and the monthly charges are added to your cart. 11. Click **Review Order** to deploy the new LAGs now, or click **Save** to save the configured LAGs before placing the order. 12. Click **Order Now** on the pop-up window to start provisioning your new LAGs. After the LAGs are provisioned, Megaport generates a Letter of Authorization (LOA) specifying the demarcation point to be applied to your service. 13. Click **Download LOA** next to the new LAGs on the Services page.\ Megaport will also send you the LOA PDF by email. 14. Provide the LOA to your data center operator to establish the physical Cross Connect from your network device to your new Port. The cost of a new cross connection and any related VXC fees are the responsibility of the customer, as outlined in [Megaport's Global Services Agreement](https://www.megaport.com/legal/global-services-agreement/). After the LAGs have been provisioned and deployed, you have access to the Megaport network and can start adding Virtual Cross Connects (VXCs) to the LAG. For more information about adding VXCs, see [Creating a VXC](/connections/overview#create_vxc). ## Converting a non-LAG Port To convert a non-LAG Port to a LAG, send a request to Megaport Support to manually convert the Port. Make sure to identify the Port in your request. # Adding a Port to an Existing LAG Source: https://docs.megaport.com/connections/lag-adding This help topic describes how to add a Port to an existing Link Aggregation Group. The most simple LAG configuration is a single Port LAG, which configures the device on the Megaport side to run LACP on a single channel. However, this configuration doesn’t provide any added resilience. If Port capacity or traffic status requires resilience, you can add Ports to a LAG. For example, if traffic moves from development to production, you might require additional Ports. When you add one or more Ports to a live LAG, they are automatically assigned the same location, speed, and Megaport Marketplace visibility as other Ports in the LAG. Any Ports that you add to a diverse LAG will inherit the diversity zone of the LAG. **To add a Port to an existing LAG** 1. Log in to the Megaport Portal and choose **Services**. 2. Select a Port that is part of a LAG and click **+Ports**. Adding a Port to a LAG 3. Specify these details for the new Port: * **Port Speed** -- Select the required Port speed. Port capacity depends on location and service availability. Ensure that your equipment is capable of interfacing with the selected speed. If Port diversity is available at the location and speed you select, Port diversity options are enabled. If Port diversity is not available at your preferred location, contact a Megaport Sales representative for more information. * **Port Name** -- Specify an easily identifiable name for the Port. * **Megaport Marketplace** -- By default, each service is private to your enterprise and consumes services from the Megaport network for your own internal company, team, and resources. When set to private, the service is not searchable in the Megaport Marketplace, however, others can still connect to you using a [service key](/marketplace/service-keys). Megaport Marketplace visibility is controlled on your Megaport Marketplace profile. For more information about how to make your service visible to the Megaport Marketplace, see [Adding services to your profile](/marketplace/profile#adding-services-to-your-profile). * **Service Level Reference** (optional) -- Specify a unique identifying number for your Megaport service to be used for billing purposes, such as a cost center number, unique customer ID, or purchase order number. The service level reference number appears for each service under the Product section of the invoice. You can also edit this field for an existing service. * **Cross Connect** -- If the location has Cross Connect availability, a option appears in the Add-ons section. Enable the **Cross Connect** add-on to add a Cross Connect to your Port order. The monthly rate and one-time fee for the Cross Connect appear on the card. For more information, see [Ordering a Cross Connect](/connections/cross-connect/). * **Minimum Term** -- Select No Minimum Term, 12 Months, 24 Months, 36 Months, 48 Months, or 60 Months. Longer terms result in a lower monthly rate. *12 Months* is selected by default. Take note of the information on the screen to avoid early termination fees (ETF). Enable the [Minimum Term Renewal](/portal-admin/auto-renew/#auto-renew) option for services with a 12, 24, 36, 48 or 60-month term to automatically renew the contract at the same discounted price and term length at the end of the contract. If you don't renew the contract, at the end of the term, the contract will automatically roll over to month-to-month contract for the following billing period, at the same price, without term discounts. For more information, see [Port Pricing and Contract Terms](/finance/port-pricing). Partner and partner-managed accounts cannot view or change Port contract terms. * **Port Diversity** -- Diversity options are displayed only if diversity is available at this location and speed. * **LACP & LAG Ports** -- Specify the number of Ports to add to the LAG from the drop-down list. The maximum number of Ports in a LAG is 8. * **Resource Tags** -- You can use resource tags to add your own reference metadata to a Megaport service.\ To add a tag: 1. Click **Add Tags**. 2. Click **Add New Tag**. 3. Enter details into the fields: * **Key** -- String, maximum length 128 characters. Valid values are a-z 0-9 \_ : . / \ - * **Value** -- String, maximum length 256 characters. Valid values are a-z A-Z 0-9 \_ : . @ / + \ - (space) 4. Click **Save**. If you already have resource tags for that service, you can manage them by clicking **Manage Tags**. Never include sensitive information in a resource tag. Sensitive information includes commands that return existing tag definitions and information that will identify a person or company. New Port details 4. Click **Next**.\ The price updates dynamically based on your selections. 5. Click **Review Order** to proceed through the checkout process, or click **Save** to save the configured services before placing the order. 6. Review the Important Information section and confirm agreement with the Service Agreements. If you do not have a promotion code, skip to the **Order Now** step. If you do have a promotion code, enter it into the **Enter discount code** field then click **Apply**. Alternatively, if a code already appears in the **Discounts** field, verify it is correct and click **Apply**. The promotional discount appears below the Standard Term discount. This discount is not reflected in the Monthly Rate shown here, it is applied at the time of billing. If an invalid or expired code causes an error with your order, contact your Megaport Account Manager for a replacement code. Add Promo Code If you entered an incorrect promotion code, you can remove it by clicking **Remove**. In addition to entering a promotion code manually, there are two other ways to apply promotion codes. * **Auto-apply** -- Megaport automatically applies the promotion code to your order. It appears automatically on the Checkout page. * **Manual list** -- Eligible promotion codes appear at checkout for any applicable services in your cart. You can then select and apply them. 7. Click **Order Now**. # Ordering a Local Loop Source: https://docs.megaport.com/connections/local-loop This help topic describes what a Local Loop is and how to use it A local loop, also known as a last-mile connection, is the external circuit that links your site, which is located outside a Megaport-enabled data center, to the designated Megaport-enabled data center. This connection is often a circuit that utilizes fiber outside the Megaport data center. The network diagram below illustrates the architecture and functionality of the local loop. Local loop network diagram ## Local loop procurement and Megaport's role A local loop is typically procured and managed directly by you or a third-party carrier. When a local loop is required to deliver Megaport services, Megaport provides proactive procurement support and works closely with both you and the Megaport-procured third-party carrier to streamline, speed up, and simplify the process. However, since local loop provisioning remains a manual process, unlike Megaport's generally automated ordering system, it will require additional time to complete. The Port will only be live after the local loop has been delivered. Therefore, when ordering a Port that includes a local loop, you should expect the Port’s availability to be delayed, as it depends on the local loop delivery timeline. ## Local loop ordering workflow Below is a step-by-step workflow describing how you can order a local loop through Megaport. 1. Contact your Megaport Account Manager to provide the required technical details for your local loop connection. 2. After the technical details are confirmed by you, the Megaport Account Manager, and the Megaport Solutions Architect, the request will be evaluated by the Megaport technical and support teams to determine feasibility, final delivery timeline, and total cost. 3. After Megaport determines that the proposed solution is feasible, the Megaport Account Manager will provide you with a Megaport Local Loop Service Order Form (MSO) for your review and acceptance of the pricing and terms and conditions. 4. After you sign the MSO, you create a Port in the Megaport Portal with minimum term of 24 months. For more information, see [Creating a Port](/connections/creating-port). 5. Megaport orders the local loop under a contract established between the carrier and Megaport. 6. Megaport will then place a Cross Connect order to establish the physical connection between your Port and the local loop demarcation point. 7. The Megaport Account Manager and the Megaport team will coordinate with you to bring the Port to the *Live* status by monitoring the Port’s light levels. If required, a troubleshooting process might be conducted involving the Megaport Account Manager, the Megaport technical team, you, and the carrier. ## Summary of ordering a local loop 1. **Early engagement** -- If you require a local loop to connect to a Megaport-enabled data center, we recommend engaging with your Megaport Account Manager as early as possible in the planning process. 2. **Port order** -- After the local loop procurement details are finalized among you, your carrier contact, and Megaport, you can proceed to order a Port. The minimum term for a Port associated with a local loop is 24 months. 3. **Local loop order placement** -- After the Port order is created and the Port is in the *Configured* status, Megaport will order the local loop service. ## Helpful references * [Creating a Port](/connections/creating-port) * [Megaport Enabled Locations page](https://www.megaport.com/megaport-enabled-locations/) * [Port Pricing and Contract Terms](/finance/port-pricing) * [Understanding Locations](/enabled-locations) # Moving VXCs Source: https://docs.megaport.com/connections/move-vxc This help topic describes how you can move one or more ends of a VXC in the Megaport Portal. Once you have created and deployed VXCs on the Megaport network, you can move one or both ends, subject to some rules. You can move VXCs on Ports, MCRs, and MVEs. This is a useful function for reducing interruptions during maintenance and other tasks that would otherwise cause downtime. ## Which VXCs can be moved? The following rules apply regarding which VXCs you can move: * Any user who can change the speed of a VXC is allowed to move the VXC from any account type. * You can move any VXC type as long as it is not locked or pending approval. * You can move an unlocked VXC under a locked Port. * No approval is required for Megaport Marketplace or Service Key VXCs. * The source and destination Ports must be owned by the same customer account. ## Conditions for moving a VXC There are conditions that must be met before moving a VXC. The following criteria must be satisfied before you can move a VXC. * The move can only be to a service of the same type.\ For example, Port to Port, MCR to MCR, or MVE to MVE. * You can only move to a Port within the same metro as the current Port.\ For more information about metros, see [Metro IDs](/ix/metro-ids). * The destination Ports must have enough capacity for the selected connection. * When a VLAN is specified, that VLAN must be available on the destination Port. * The move must not cause a change to billing. If a move is regarded as invalid, the connection will be greyed out and cannot be moved. If you cancel a move, the VXC is not affected and it remains connected to its original Port. ## Moving VXCs on MVEs Moving a VXC on an MVE supports MVEs with multiple vNICs. When moving VXCs for MVEs with multiple vNICs, you can: * move a VXC to a different vNIC on the same MVE. * select the required vNIC on the destination MVE when moving a VXC between different MVEs. ## Moving one or more VXCs You can move one or more VXCs at a time. Select the service that the VXCs are to be moved from, then select the VXCs to be moved. This example shows how to move a VXC on a Port. **To move one or more VXCs** 1. In the Megaport Portal, go to the **Services** page and select the Port you want to use. The A-End and B-End of the VXC are shown as connections on the relevant Port. Make sure you are moving the correct end. This image shows the A-End and B-End ports and the VXC top-level details from the Services page. The place where A-End or B-End is specified is circled in red. 2. Click the **Move Connections** icon on the Port or on the VXC. The **Move Connections** icon is greyed out if the Port or VXC is not valid. For more information, see [rules](#which) and [conditions](#conditions) above. This image shows the A-End port and a list of VXC top-level details from the Services page. The Move VXC button is shown on the port and on each VXC. 3. Click to select one or more connections to move. Each move is subject to the [rules](#which) and [conditions](#conditions) described above. If a connection is not valid, it will be displayed but will not be available to select. You can select or deselect connections individually, or use the **Select All** button. This image shows the list where you can select the VXCs to move. 4. Select the destination Port in the Move To area. The Port selection list is filtered by the rules described in the [rules](#which) and [conditions](#conditions) described above. If a connection is not valid, it will be displayed but will not be available to select. You can filter the Ports by selecting a diversity zone at the top of the Move To list. 5. Click **Next**. 6. Review your selection and click **Move**. This image shows the confirmation window. It lists the source and destination of the move, and presents two buttons - Confirm and Cancel. 7. On the prompt that shows the intended move, review the details again and click **Confirm**. This image shows the confirmation window. It lists the source and destination of the move, and presents two buttons - Confirm and Cancel. The Summary table shows the status of the move. It will either show a *working* hourglass, a message saying *success*, or an error message. The *Success* status means that the request was successfully submitted and the VXC(s) have been moved. A *Failure* message shows that the move has failed. The connections will not be moved. This image shows the confirmation pop-up window. It lists the source and destination of the move, and presents two buttons - Confirm and Cancel. # Connections Overview Source: https://docs.megaport.com/connections/overview This help topic describes the network connection models available through Megaport. Megaport lets you connect to the services you need, when you need them. The process is simple and fast, and involves these basic steps: 1. Create a [Port](/connections/creating-port), [Megaport Cloud Router (MCR)](/mcr/creating-mcr), or [Megaport Virtual Edge (MVE)](/mve). 2. Deploy . 3. Use the VXCs to connect to services on the Megaport network. VXCs are Layer 2 Ethernet circuits providing private, flexible, and on-demand connections between any of the locations on the Megaport network with 1 Mbps to 100 Gbps of capacity. Connections over 10 Gbps are available on 100 Gbps Ports. All VXCs on the Megaport network are delivered as protected services. Each VXC is provisioned across multiple diverse fiber paths at the data center, and connections automatically fail over if an individual path becomes unavailable. ## VXC rate limits The maximum VXC size is dynamically calculated based on network routes used to deliver the service. The VXC size cannot exceed the speed of the physical interface on which it resides. * **Port and MCR** -- The VXC rate limit cannot exceed the speed of the lowest speed Port or MCR. This limit also applies to LAGs. For example, a 15 Gbps VXC is allowed on a 100 Gbps Port, but not on a 2 x 10 Gbps LAG. * **MVE** -- The maximum rate limit of a standard VXC or Megaport Internet connection is controlled by the lowest of the end rates. You can adjust the speed as required after you create the VXC, in increments of 1 Mbps. In some cases, Megaport cannot automatically provision the entered rate limit. However, we might be able to configure a higher speed for the service. To request a higher speed, submit the request form displayed below the **Rate Limit** field in the Connection Details page. ## VXC terms You can specify an optional term for your VXC. The choices are: * No Minimum Term * 12 months (this is the default) * 24 months * 36 months * 48 months * 60 months Discounts are applied depending on the term duration. For more information, see [VXC Pricing and Contract Terms](/finance/vxc-pricing). You can select No Minimum Term to pay-as-you-go at the current rack rate and adjust the rate limit as required. You can increase the rate limit of a termed VXC during the term. For more information, see [Changing the Speed of a Termed VXC](/connections/vxc-termed-rate-change). Deleting a VXC before the end of the term will generate early termination fees (ETF), which are also known as early termination charges (ETC). To avoid ETF, select No Minimum Term until the configuration is complete. You can update the connection at any time to opt into a term. For more information, see [VXC Pricing and Contract Terms](/finance/vxc-pricing) and [VXC, Megaport Internet, and IX Billing](/finance/billing-details). ## Creating a VXC After you configure a Port, you can create VXCs to connect to services on the Megaport network. A VXC is a private point-to-point Ethernet connection between your A-End Port and a B-End destination (CSPs, Ports, Megaport Marketplace services, or IX). For CSP and Private VXCs, when the A-End and B-End are in the same data center location, we recommend matching the Port, MCR, or MVE diversity zone color to the B-End diversity zone color. For example, A-End to B-End is recommended to be *Red to Red* or *Blue to Blue*. **To create and deploy a VXC** 1. In the Megaport Portal, go to the **Services** page and select the Port you want to use.\ If you haven't already created a Port, see [Creating a Port](/connections/creating-port). 2. Click **+Connection**.\ For CSPs, Megaport Internet, and IX, you can click the tile as a shortcut. Add Connection 3. Choose your destination type. * **Cloud** -- Connectivity to global cloud providers (CSPs), including Amazon Web Services (AWS), Microsoft Azure, and Google Cloud Platform.\ For more information about connecting to CSPs, see [Cloud Connectivity](/cloud/megaport). * **Private VXC** -- Connectivity between two locations for a single organization or service provider, traditionally called data center backhaul or Data Center Interconnect (DCI). You can use private VXCs as a core network backbone, or for connecting production and disaster recovery (DR) data centers.\ For more information about creating private VXCs, see [Creating a Private VXC](/connections/private-vxc). * **Megaport Internet** -- A scalable, on-demand service that allows you to connect to the internet from Ports, MCRs, and MVEs. Connections are available where internet routers are deployed.\ For more information about Megaport Internet, see [Megaport Internet Overview](/megaport-internet). * **Internet Exchange (IXs)** -- Megaport owns and operates a series of local internet peering exchanges in many global markets. IXs provide greater efficiency between networks and allow for traffic to be exchanged directly, reducing bandwidth usage on your internet connections.\ For more information about IX, see [Internet Exchange Overview](/ix) or [AMS-IX Connectivity](/ix/ams). * **Megaport Marketplace** -- Connectivity between two different customers located in any of the Megaport Points of Presence (POPs). The Megaport Marketplace connects service providers to enterprise customers while removing the boundaries around physical location.\ For more information about the Megaport Marketplace, see [Megaport Marketplace Overview](/marketplace/overview). * **Service Key** -- A service key is a code that is given by one Megaport account holder to another to connect two separate businesses together. Customers who have separate Megaport accounts can connect their Ports to each other across the Megaport network, enabling business-to-business VXCs.\ For more information about service keys, see [Setting up Service Keys](/marketplace/service-keys). * **Megaport Object Storage** -- A dedicated Virtual Cross Connect (VXC) to your S3-compatible object storage provisioned with Latitude.sh.\ For more information about Megaport Object Storage, see [Megaport Object Storage Overview](/storage/object). 4. Step through the procedures to configure your VXC.\ The procedures will vary slightly depending on your destination type. 5. Add the VXC to your order and configure further VXCs or proceed through the checkout process. **To edit a VXC** * Click the gear icon next to the connection in the Megaport Portal. Edit a VXC You can modify the details on the Megaport side including the connection name, rate limit, VLAN ID, invoice reference, and contract term. You can put the VXC on a term, or change the selected contract term. Once submitted, those changes take effect in a few minutes. You can change the rate limit when a VXC is on a 12, 24, 36, 48, or 60-month term. For more information, see [Changing the Speed of a Termed VXC](/connections/vxc-termed-rate-change). # Port Diversity Source: https://docs.megaport.com/connections/port-diversity This help topic describes how to configure and manage diverse Ports. This topic describes how to configure and manage . Port diversity improves the robustness of your network by providing Port services on different physical devices at a single Megaport location. Ports are assigned to diversity zones. A diversity zone groups devices at the same location to ensure that services are provisioned on physically separate devices that always remain diverse. Assigning Ports to diversity zones reduces the risk of service interruption due to an impacting event on a single device. For example, during scheduled maintenance, no more than one diversity zone at a given data center location will experience downtime at any moment. If a Port in a diversity zone experiences scheduled downtime, Ports in the other zone at the same location are not affected by that same scheduled maintenance. Ports deployed at locations supporting diversity are zoned into one of two groups - red or blue. In the Megaport Portal, the Services page **List** view shows a Port's diversity zone assignment as a red or blue label once the Port is live. While a Port is in **Configured** status awaiting its physical Cross Connect, the List view shows a **Download LOA** action in place of the diversity zone label. This information is not shown in the Services page **Diagram** view. Services page row for a Port showing a Diversity Zone label set to Blue At locations where diversity is supported, you can: * Create a new Port on a device that is diverse from an existing Port * Create multiple Ports or LAG bundles as a diverse pair in the same order ## Configuring a Port for diversity When you create a new Port, you can make it diverse from an existing Port or create a diverse pair of Ports at the same time, with one in each diversity zone. A Port ordered to a specific zone always remains in that zone. To change a Port diversity zone after placing the order, you must cancel and re-order the Port. **To configure a Port for diversity** 1. Log in to the Megaport Portal and choose **Services**. 2. Click **Add Services**, then select **Port**. Add Services button The Create Port page opens. 3. In the **Details** section, specify a **Port Name**, then in the **Location** section, select a data center location for the Port.\ Use the **Search** field to find a location by metro name, country, data center name, or provider name. You can also search by address details, such as a street, city, state, or postcode. Alternatively, browse the region tabs, then select a location. 4. In the **Provider** section, select a data center provider and data center.\ Only providers and data centers available at your selected location are listed. If your search term in the Location section matches a specific provider or data center, the Provider list narrows to that provider. If the term matches only a metro or country, the Provider list shows every provider available at that location. 5. In the **Configuration** section, specify these fields: * **Port Speed** -- Select the required Port speed. Port capacity depends on location and service availability. Ensure that your equipment is capable of interfacing with the selected speed. If Port diversity is available at the location and speed you select, a **Diversity Option** drop-down list is enabled. If Port diversity is not available at your preferred location, contact a Megaport Sales representative for more information. * * **LACP & LAG Ports** -- Enable LACP on Port if you want the Port to be a member of a LAG. To enable LACP, the Port speed must be 10 Gbps or higher. Select the number of Ports in the LAG, up to a maximum of 8. For more information about LAG, see [Creating a Link Aggregation Group](/connections/lag). Configuration section showing the Diversity Option drop-down list with None, Create Diverse Pair, and Diverse from Existing Port options 6. In the **Pricing** section, select a **Contract Term** and set **Contract Renewal**. For more information, see [Port Pricing and Contract Terms](/finance/port-pricing). 7. In the **Add-ons** section, review the following: * **Cross Connect** -- If the location has Cross Connect availability, a option appears in the Add-ons section. Enable the **Cross Connect** add-on to add a Cross Connect to your Port order. The monthly rate and one-time fee for the Cross Connect appear on the card. For more information, see [Ordering a Cross Connect](/connections/cross-connect/). 8. In the **Resource Tags** section, add any tags you want to apply. * **Resource Tags** -- You can use resource tags to add your own reference metadata to a Megaport service.\ To add a tag: 1. Click **Add Tags**. 2. Click **Add New Tag**. 3. Enter details into the fields: * **Key** -- String, maximum length 128 characters. Valid values are a-z 0-9 \_ : . / \ - * **Value** -- String, maximum length 256 characters. Valid values are a-z A-Z 0-9 \_ : . @ / + \ - (space) 4. Click **Save**. If you already have resource tags for that service, you can manage them by clicking **Manage Tags**. Never include sensitive information in a resource tag. Sensitive information includes commands that return existing tag definitions and information that will identify a person or company. 9. Review the order summary.\ The summary shows Port Diversity enabled and the diversity zones for the Ports. If you created a diverse pair of Ports, the monthly charge includes both Ports. If a Cross Connect has been ordered, the summary also shows the monthly rate and the one-time fee for the Cross Connect. 10. Click **Add Port**.\ The newly created Ports, their diversity zones, and the monthly charges are added to your cart. 11. Click **Review Order** to deploy the new Ports now, or click **Save** to save the configured services before placing the order. 12. Click **Create Port** to add more Ports in other locations or click **Order Now** to start provisioning your new Ports. After the Ports are provisioned, Megaport generates Letters of Authorization (LOAs) specifying the demarcation point to be applied. 1. Click **Download LOA** next to the new Ports on the Services page.\ Megaport will also send you the LOA PDF by email. 2. Provide the LOAs to your data center operator to establish the physical Cross Connects from your network device to your new Ports. The cost of a new cross connection and any related VXC fees are the responsibility of the customer, as outlined in [Megaport's Global Services Agreement](https://www.megaport.com/legal/global-services-agreement/). After the Port has been provisioned and deployed, you have access to the Megaport network and can start adding Virtual Cross Connects (VXCs) to the Port. For more information about adding VXCs, see [Creating a VXC](/connections/overview#create_vxc). # Creating a Private VXC Source: https://docs.megaport.com/connections/private-vxc This help topic describes how to connect a private VXC (Virtual Cross Connect) to a Port in the Megaport network. This topic describes how to connect a private Virtual Cross Connect (VXC) to a Port in the Megaport network. With a Port configured, you can deploy a private VXC to connect to another Port local to the current company account. A private VXC is essentially a point-to-point Ethernet connection between an A-End (your Port) and a B-End (the Private VXC destination type). For example, you could create an interconnect within a data center to extend your private network backbone capability, or connect a production data center to a redundant data center for disaster recovery. For more information about creating a private VXC for Megaport Cloud Router (MCR), see [Creating an MCR VXC](/mcr/mcr-vxc). **To deploy a private VXC** 1. In the Megaport Portal, go to the **Services** page and select the Port you want to use. If you haven't already created a Port, see [Creating a Port](/connections/creating-port). 2. Select the originating Port (the A-End). 3. Click **+Connection**. Create private VXC Port details including the speed, location, and diversity zone are displayed. The diversity zone for an A-End service is visible after the service is deployed and available. The A-End diversity zone is also visible when ordering a diverse pair of Ports. When creating an order with multiple VXCs and diverse Ports, the Port diversity zone will be visible before deploying, preventing you from accidentally crossing zones. When ordering a single Port, you will not see the diversity zone until it is deployed, and not at all if the location does not support diversity. 4. Click **Private VXC**. The **Private VXC** tile is disabled in the following scenarios: * You only own one Port, MCR, or MVE. You cannot create a private connection with the same port at both ends. * You have more than one Port but no MCRs or MVEs, and the other owned Ports have untagged connections. 5. Select the target Port (the B-End) then click **Next**. For the B-End, the Port details including the speed, location, and diversity zone are displayed. The diversity zone for a B-End service is visible after the service is deployed and available. The B-End diversity zone is also visible when ordering a diverse pair of Ports. When creating an order with multiple VXCs and diverse Ports, the Port diversity zone will be visible before deploying, preventing you from accidentally crossing zones. When ordering a single Port, you will not see the diversity zone until it is deployed, and not at all if the location does not support diversity. 6. Specify the connection details: * **Connection Name** -- The name of your VXC to be shown in the Megaport Portal. * **Service Level Reference** (optional) -- Specify a unique identifying number for your Megaport service to be used for billing purposes, such as a cost center number, unique customer ID, or purchase order number. The service level reference number appears for each service under the Product section of the invoice. You can also edit this field for an existing service. * **Rate Limit** -- The speed of your connection in Mbps. The maximum VXC size is dynamically calculated based on network routes used to deliver the service. The calculation uses the Ports at each end of the VXC and bases calculations on the lowest rate. The whole path must be able to support the VXC speed. An error will appear if you try to specify a rate limit that is too high for the path to support. * **VXC State** -- Select **Enabled** or **Shut Down** to define the initial state of the connection. For more information, see [Shutting Down a VXC for Failover Testing](/connections/shut-down-vxc). If you select **Shut Down**, traffic will not flow through this service and it will behave as if it was down on the Megaport network. Billing for this service will remain active and you will still be charged for this connection. * **Preferred A-End VLAN** -- Specify the 802.1q VLAN tag for this connection for the A-End.\ Each VXC is delivered as a separate VLAN on your Port. This must be a unique VLAN ID on this Port and can range from 2 to 4093. If you specify a VLAN ID that is already in use, the system displays the next available VLAN number. The VLAN ID must be unique to proceed with the order. If you don’t specify a value, Megaport will assign one. You can select **Untagged** to deliver an untagged VLAN; however, this consumes the entire Port and prevents any other VXCs from being deployed on this Port. * **Preferred B-End VLAN** -- Specify the 802.1q VLAN tag for this connection that you will receive through the B-End VLAN. Selecting **Untagged** for the A-End and B-End provides point-to-point Ethernet connectivity between a pair of dedicated Ports, supporting the forwarding of both untagged and tagged frames (IEEE 802.1q and 802.1ad). Additionally, other protocols like MACsec (802.1ae) will also be forwarded. For supported protocols, frame types, and behaviors, see [Technical Specifications](/tech-specs). * **Minimum Term** -- Select No Minimum Term, 12 Months, 24 Months, 36 Months, 48 Months, or 60 Months. Longer terms result in a lower monthly rate. *12 Months* is selected by default. Take note of the information on the screen to avoid early termination fees (ETF). Enable the [Minimum Term Renewal](/portal-admin/auto-renew/#auto-renew) option for services with a 12, 24, 36, 48 or 60-month term to automatically renew the contract at the same discounted price and term length at the end of the contract. If you don't renew the contract, at the end of the term, the contract will automatically roll over to month-to-month contract for the following billing period, at the same price, without term discounts. For more information, see [VXC Pricing and Contract Terms](/finance/vxc-pricing) and [VXC, Megaport Internet, and IX Billing](/finance/billing-details). * **Resource Tags** -- You can use resource tags to add your own reference metadata to a Megaport service.\ To add a tag: 1. Click **Add Tags**. 2. Click **Add New Tag**. 3. Enter details into the fields: * **Key** -- String, maximum length 128 characters. Valid values are a-z 0-9 \_ : . / \ - * **Value** -- String, maximum length 256 characters. Valid values are a-z A-Z 0-9 \_ : . @ / + \ - (space) 4. Click **Save**. If you already have resource tags for that service, you can manage them by clicking **Manage Tags**. Never include sensitive information in a resource tag. Sensitive information includes commands that return existing tag definitions and information that will identify a person or company. Create private VXC 7. Click **Next** to review the VXC connection summary, including price. 8. Click **Add VXC** to save the VXC.\ Repeat these steps to configure more VXCs. 9. Click **Review Order** to proceed through the checkout process, or click **Save** to save the configured services before placing the order. 10. Review the Important Information section and confirm agreement with the Service Agreements. If you do not have a promotion code, skip to the **Order Now** step. If you do have a promotion code, enter it into the **Enter discount code** field then click **Apply**. Alternatively, if a code already appears in the **Discounts** field, verify it is correct and click **Apply**. The promotional discount appears below the Standard Term discount. This discount is not reflected in the Monthly Rate shown here, it is applied at the time of billing. If an invalid or expired code causes an error with your order, contact your Megaport Account Manager for a replacement code. Add Promo Code If you entered an incorrect promotion code, you can remove it by clicking **Remove**. In addition to entering a promotion code manually, there are two other ways to apply promotion codes. * **Auto-apply** -- Megaport automatically applies the promotion code to your order. It appears automatically on the Checkout page. * **Manual list** -- Eligible promotion codes appear at checkout for any applicable services in your cart. You can then select and apply them. 11. Click **Order Now**. When the VXCs are deployed, you can view them in the Portal Services page. Note that the service identifier number is the same for the VXCs at both ends of the connection. You can change the rate limit when a VXC is on a 12, 24, 36, 48, or 60-month term. For more information, see [Changing the Speed of a Termed VXC](/connections/vxc-termed-rate-change). # Configuring Q-in-Q Source: https://docs.megaport.com/connections/q-in-q This help topic describes ways to connect your on-premises network equipment to a CSP that uses Q-in-Q in the Megaport network. This topic describes ways to connect your on-premises network equipment to a Cloud Service Provider (CSP) that uses , such as Azure ExpressRoute. In addition, because some CSPs require Q-in-Q, but not all network devices support it, or the mixing of single and multiple tags on a single physical interface (“selective Q-in-Q”), this topic includes ways to configure multiple layer VLAN tag handling on network devices without native Q-in-Q support. ## Q-in-Q overview Q-in-Q, also known as 802.1ad, is a protocol commonly used by network service providers (NSPs) to provide more Layer 2 flexibility. Q-in-Q allows multiple VLAN tags to be inserted into a single Ethernet frame. Stacking multiple VLAN tags in a frame allows isolation of routing domains, because the additional tags identify and separate customer traffic. By using a different VLAN tag for each customer, the traffic is identified within the frame and is transferred throughout the service provider network. To differentiate the VLAN tags under the 802.1ad standard, the inner commonly uses EtherType 0x8100 and the outer uses 0x88a8. The default configuration for most network vendors' Q-in-Q is for both inner and outer EtherTypes to be 0x8100. The Megaport specification of double-tagged frames is for both inner and outer tags to be 0x8100. With Q-in-Q, as a packet travels from an NSP or carrier network to a cloud (or other) service provider’s VLAN, inner VLAN tags (C-Tags) that identify the customer traffic are inserted inside of the outer VLAN tags (S-Tags) provided by the service provider. The S-Tag provides a single VLAN that encapsulates multiple VLANs within it. In this configuration, a single VXC may carry the multiple VLAN tags between the two network endpoints. For more information about Q-in-Q, see [Connecting a VXC](/mcr/mcr-vxc#connectavxcmcr) and the [Megaport blog post *Q & A for Q-in-Q: Part 1*](https://www.megaport.com/blog/q-in-q-questions-answered-part-1/). For more information about configuring Q-in-Q for Azure, see the [Megaport blog post *Q & A for Q-in-Q: Part 2*](https://www.megaport.com/blog/q-in-q-questions-answered-part-2/). ## Understanding Q-in-Q with Megaport VXCs A Virtual Cross Connect (VXC) is a point-to-point Layer 2 circuit between two endpoints that is mapped with a VLAN ID on each end, optionally with A and B-End VLAN tags being independently mapped across the Megaport network. This image shows an Azure ExpressRoute with private peering and Microsoft Peering enabled. A VXC connects a customer edge to a Microsoft edge on VLAN 1000 (S-Tag). The customer edge supports Q-in-Q. The private peering is running on VLAN 100 (C-Tag) and Microsoft Peering is running on VLAN 200 (C-Tag) to establish Layer 3 connections and BGP peering with Azure. Q-in-Q with VXCs ### What if my routers or switches don't support Q-in-Q? This section describes ways to connect to a B-End service that requires Q-in-Q even when the network equipment terminating your Megaport connection doesn’t natively support it. | **Q-in-Q Alternatives** | **Method** | **Drawbacks** | | :- | :- | :- | | **Single Azure peering VLAN** | You can configure the VXC so that Megaport removes the Q-in-Q requirement by remapping one of the B-End VLAN IDs for Private Peering or Microsoft Peering to the customer Megaport-facing VLAN (A-End). | You can only use a single Microsoft peering type per VXC. | | **Untag the VXC attached to the customer Port** | You can configure the VXC as untagged to automatically remove the S-Tag. | Untagging a VLAN limits the Port to a single VXC connection. Employing this method means that your Port will only be able to configure a single B-End target, although it will receive all inner/C-Tags from that peer as single/dot1q tagged. | | **Deploy a Megaport Cloud Router** | You can deploy a Megaport Cloud Router (MCR) to automatically manage the Q-in-Q requirements for one or both peering types. | Additional cost of the MCR and additional VXC to MCR. | A VXC connecting to Microsoft ExpressRoute may contain one or two inner VLAN tags. These are the C-tags configured in the Microsoft Azure console for the specified peering type. Note that Q-in-Q is a requirement in this scenario, even if only a single Microsoft edge device (primary or secondary) or peering type (private or Microsoft) is employed. Network equipment that supports Q-in-Q is able to access these inner tags by stripping the outer VLAN tag (S-Tag). If your network equipment does not support Q-in-Q, it cannot access the inner tags. Other Q-in-Q workarounds exist, such as handling at the customer side via multiple devices to de-encapsulate the Q-in-Q frames, or using loopback cables within a single device to manage this via cascading through multiple ports with different VLAN configurations for inner and outer tags. However, this is generally not recommended in production networks. ## Single Azure peering VLAN For Microsoft Azure ExpressRoute connections, Megaport uses a Microsoft Service Key (and associated primary and secondary target endpoint selection) and provides the ability to *break out* the encapsulated C-Tag for a specified Azure peering type. You enable this functionality by enabling the Configure Single Azure Peering VLAN in the Connection Details panel of a new ExpressRoute connection, after selecting a primary or secondary target B-End port. We recommend using the Single Azure Peering VLAN option. This option provides full functionality and the simplest implementation. With Single Azure VLAN, you can use both private or Microsoft peering with a single ER circuit without the need for Q-in-Q capable equipment, an MCR, or an untagged port. Note, you can have only one peering type (private or Microsoft) per VXC with this option so you need two VXCs to use both peering types. By enabling the Single Azure VLAN Peering VLAN functionality, you can specify a single Azure peering VLAN that will match with the value that you configure (in a future step) for the selected Peering type configuration for the Azure ExpressRoute configuration (via Microsoft Azure portal or other configuration method). For more information, see [Tutorial: Create and modify peering for an ExpressRoute circuit using the Azure portal](https://docs.microsoft.com/en-us/azure/expressroute/expressroute-howto-routing-portal-resource-manager). Azure peering example If you leave the **Preferred A-End VLAN** field blank, a randomly chosen VLAN will be assigned for your VXC when you place the order, otherwise enter a VLAN and a validation check will be performed to ensure this VLAN is available. This example shows that an Azure C-tag value of 200 (for either a Private or Microsoft peering type on the associated ExpressRoute circuit) is mapped transparently to a single-tagged VXC VLAN value of 3001. That is, the customer device attached to the physical Megaport interface need not be configured for any Q-in-Q settings, as dot1q VLAN 3001 will be conferred to the associated Microsoft facing B-End edge device as correctly labelled. In this configuration, it is possible to use both the primary and secondary Microsoft ExpressRoute endpoints on a given ExpressRoute circuit to map to different VLAN tags on a single customer-side port. This is compliant for the purposes of the Azure ExpressRoute Service Level Agreement (SLA). However, we recommend that you employ either single site port and device (zonal) diversity, or split the primary/secondary ExpressRoute connections across two Megaport-enabled locations to ensure no single point of failure exists with the configuration. For more information about Azure ExpressRoute SLA, see [SLA for Azure ExpressRoute](https://azure.microsoft.com/en-us/support/legal/sla/expressroute/v1_3/). With this method, it is not possible to use more than one peering type across either of the primary or secondary ExpressRoute facing VXCs, as this tag translation may only occur once per VXC circuit path. Further workarounds are detailed in the following sections, however, note that segmentation of bandwidth between multiple peering types on a single ExpressRoute circuit pair is not currently supported by Microsoft. In most cases, it is preferred to deploy two ExpressRoute pairs to achieve this configuration goal. The following sections describe workarounds that continue with the Microsoft ExpressRoute example. Note that these workarounds are not unique to Azure endpoints and may also be used for other connections across Megaport where the B-End might specify or require Q-in-Q to carry multiple C-Tag/inner VLANs within a single S-Tag/outer VXC VLAN. The Microsoft ExpressRoute example is used for continuity of the customer scenario. ## Configure the VXC as untagged to automatically manage the S-Tag Using this method means that the customer Port will only be able to configure a single B-End target, though it will receive all inner/C-tags from that peer as single/dot1q tagged. You can configure the VXC so Megaport removes the outer VLAN (S-Tag) and presents one or both of the inner VLAN (C-Tag/s) for Private Peering, Microsoft Peering, or both, to the customer Port. Currently, this process allows only one VXC per ExpressRoute Circuit Connection (selecting from Primary or Secondary port presentation), although both peering types can be supported across this VXC as they will be presented to the customer port as one or two dot1q VLANs (Private, Microsoft Peering, or both). Untagged VXC The customer port will receive the inner VLAN tags as defined on the Azure portal under the specified peering type at the A-End customer port. For more information, see [Connecting to Microsoft Azure ExpressRoute](/cloud/megaport/microsoft). * Each ExpressRoute subscription includes two port targets at the chosen Microsoft edge location. To take delivery of both the primary and secondary ExpressRoute circuits, you will require two ports from Megaport in this configuration. The Azure VNET VLAN tags are the same across both ports. Megaport cannot change the VLAN tag on the primary and secondary circuits and it cannot deliver the same VLAN twice on the same physical interface. * If you configure only private or public peering on the Azure ExpressRoute configuration, only the VLAN associated with the ExpressRoute service key will be available on the configured VXC, mapped one-to-one with the customer port. ## Deploy a Megaport Cloud Router The Megaport Cloud Router (MCR) supports multicloud, multi-region enablement, including support for Q-in-Q to connect to multiple cloud destinations. The S-Tags, or outer tags, belong to the A-End VLAN associated with your MCR and will transparently carry your C-Tags. The S-Tags are automatically configured when provisioning your private and public peering to Azure Cloud in the Megaport Portal. This image shows an example configuration: Q-in-Q with MCR When multiple Azure VXCs on an MCR populate the same VLAN 100 tag (private peering) and the same VLAN 200 tag (public peering), MCR manages the Q-in-Q tunnel for each Azure VXC that terminates on the MCR. Each Azure VLAN is still a separate logical interface. # Shutting Down a VXC for Failover Testing Source: https://docs.megaport.com/connections/shut-down-vxc This help topic describes how you can temporarily shut down a VXC for failover testing in the Megaport Portal. You can temporarily shut down a VXC for failover testing, redundancy, or network design testing purposes. This can be done when creating a VXC, or at a later time after you have created and deployed a VXC on the Megaport network. When a VXC has been shut down, you can view the VXC service that has been shut down and re-enable the VXC service. You can also shut down and re-enable an IX service. For more information, see [Shutting Down an IX for Failover Testing](/ix/shutting-down-an-ix). ## VXC shutdown overview When creating and deploying a VXC on the Megaport network, you can decide whether to set the initial state of the connection to enabled (default) or shut down. The A-End of an *Active* VXC can be shut down for failover testing and re-enabled once testing is complete. Active VXCs have a provisioning status of Configured, Live, Canceled, or Canceled\_Parent. In the Megaport Portal, the Services page shows the gear icon next to the VXC in bold when the service has been shut down, and the text (Shut Down) is displayed next to the service status. VXC Connection Shut Down in Services Page A VXC that has been shut down can still be edited, locked, and terminated. You can view service logs and usage reports for a VXC. In the Service Logs, the shutdown action for a VXC is recorded as an event and time stamped. In the Service Graph usage details, the service will go down when it has been shut down. For more information, see [Monitoring Ports, VXCs, Megaport Internet, and IXs](/monitoring/port-vxc-monitoring). You can also use the Megaport API to shut down and re-enable VXCs. For more information, see [Shutting Down a VXC and IX with the API](/api/api-vxc-shut-down). * Billing is **not** suspended during the period when a VXC is shut down. * As per any VXC speed changes, the shut down/enabled state can take up to two minutes to take effect and be updated in the Megaport Portal. * For Megaport Marketplace connections, only the A-End company can shut down a service. The B-End can see the state but cannot change it. ## Who can shut down a VXC? Users who have editing rights with the Company Admin, Technical Admin, and Technical Contact roles and are able to update a service can shut down and re-enable a VXC. * If a partner shuts down the VXC of a managed account, the partner or the managed account can both re-enable the VXC. * If a managed account shuts down their own VXC, this can be re-enabled by either the partner or the managed account. * If a user from a direct account shuts down their own VXC, this can be re-enabled by any user with editing permissions from the same direct account. ## Shutting down a VXC You can temporarily shut down a VXC for testing purposes. This can be done when creating a VXC or later when editing a VXC. This task describes how to shut down a VXC when editing a VXC. **To shut down a VXC** 1. In the Megaport Portal, go to the **Services** page and locate the VXC. 2. Click the gear icon next to the connection to make changes. Edit a VXC The Connection Configuration page appears. VXC Connection Details page 3. In the **VXC State** field, click **Shut Down**.\ A prompt appears, asking you to confirm the action. VXC Connection Shutdown prompt 4. Read the prompt then click **Confirm** and **Save**.\ The VXC is shut down. This can take up to two minutes to take effect and be updated in the Megaport Portal. VXC Connection Shut Down in the Services Page **To re-enable a VXC** 1. In the Megaport Portal, go to the **Services** page and locate the VXC that is shut down. 2. Click the gear icon next to the connection. Edit a VXC 1. In the **VXC State** field, click **Enabled**. 2. Click **Save**.\ The VXC is now enabled. This can take up to two minutes to take effect and be updated in the Megaport Portal. VXC Connection Enabled in the Services Page # Terminating a Port Source: https://docs.megaport.com/connections/terminating-port This help topic describes how to terminate a physical Port directly from the Megaport Portal. You can terminate a Port directly from the Megaport Portal. Terminating a Port on a contract term will result in an early termination fee (ETF) equivalent to 100% of the remainder of the term. For more information about Port contract terms, see [Port Pricing and Contract Terms](/finance/port-pricing). You can waive the ETF yourself by ordering an eligible replacement service. For more information, see [Managing Early Termination Fees (ETF Management)](/finance/etf-management). **To terminate a Port** 1. In the Megaport Portal, go to the **Services** page. 2. Click the trash icon next to the Port you want to terminate. Delete Port The Terminate Services window appears. Early termination fees will display here, if applicable. Terminate Port 3. In the **Cancellation Reason** drop-down list, select the reason that you are terminating the Port. We use this information to help us improve your customer experience. These options are available: * Moving to a Cloud-Native Solution * Changing Data Centers * Ordered in Error or Reordering * Proof of Concept / Test * Project Ended * Switching to Alternative Provider * Pricing * Product Performance * Reason not Listed - **Ordered in Error or Reordering** should be selected if you have upgraded or downgraded the service speed and re-ordered. - **Reason not Listed** should be selected to specify a different reason to those listed. Use the free text field to explain the reason for terminating the service. This field has a maximum of 400 characters. - You can also provide additional details in the free text field for any of the cancellation reasons. 4. Click **Yes, Terminate Service** to confirm the Port termination, or click **No, Keep Services** to cancel.\ The Port and its associated VXCs are deleted from the Megaport network. Terminating a Port that is configured as part of a diversity pair reverts the diversity setting of the other Port in the pairing. For example, if Port 1 is diverse from Port 2 and you terminate Port 2, Port 1 loses its diversity setting. You are prompted for confirmation. ## Terminating a diverse Port Usually, terminating a Port that is deployed in a diversity-enabled location is the same as terminating any other Port. However, if you configure a new, unpurchased Port to be diverse from a deployed Port, and you then delete the deployed Port, the new Port will lose its diversity setting.\ For example, consider the following scenario: * Port 1 is purchased and deployed. * Port 2 is configured to be diverse from Port 1, but you haven't finalized the order. In this scenario, if you terminate Port 1 then Port 2 will have its diversity setting removed after you confirm the termination. To reconfigure Port 2 to be diverse from a different Port, you must edit Port 2. For more information about diverse Ports, see [Port Diversity](/connections/port-diversity). # Terminating a VXC Source: https://docs.megaport.com/connections/terminating-vxc This help topic describes how to terminate a VXC directly from the Megaport Portal. You can terminate a VXC directly from the Megaport Portal. VXCs can be individually terminated or are terminated as part of terminating the attached Port, MCR, or MVE. Terminating a VXC on a contract term will result in an early termination fee (ETF) equivalent to 100% of the remainder of the term. For more information about VXC contract terms, see [VXC Pricing and Contract Terms](/finance/vxc-pricing/). You can waive the ETF yourself by ordering an eligible replacement service. For more information, see [Managing Early Termination Fees (ETF Management)](/finance/etf-management). Terminating an MVE automatically deletes all of its associated VXCs, including the Megaport Internet connection. For more information about terminating an MVE, see [Terminating an MVE](/mve/aruba/terminating-mve). **To terminate a VXC** 1. In the Megaport Portal, go to the **Services** page. 2. Click the trash icon next to the VXC you want to terminate. Delete VXC icon The Terminate Services window appears. Early termination fees will be shown here, if applicable. Delete VXC Terminate Services window 3. In the **Cancellation Reason** drop-down list, select the reason that you are terminating the VXC. We use this information to help us improve your customer experience. These options are available: * Moving to a Cloud-Native Solution * Changing Data Centers * Ordered in Error or Reordering * Proof of Concept / Test * Project Ended * Switching to Alternative Provider * Pricing * Product Performance * Reason not Listed - **Ordered in Error or Reordering** should be selected if you have upgraded or downgraded the service speed and re-ordered. - **Reason not Listed** should be selected to specify a different reason to those listed. Use the free text field to explain the reason for terminating the service. This field has a maximum of 400 characters. - You can also provide additional details in the free text field for any of the cancellation reasons. 4. Click **Yes, Terminate Service** to confirm the VXC termination, or click **No, Keep Services** to cancel.\ The VXC is deleted from the Megaport network. # Changing the Speed of a Termed VXC Source: https://docs.megaport.com/connections/vxc-termed-rate-change This help topic describes how changing the rate limit on a termed Megaport Virtual Cross Connect (VXC) works. If you have a Virtual Cross Connect (VXC) on a contract term, you can change the speed of the VXC. When you put a VXC on a contract term, you specify a rate limit, which is called the **committed term speed**. This is the minimum speed allowed on the VXC during that contract term. The maximum VXC size is dynamically calculated based on network routes used to deliver the service. The VXC rate limit size cannot exceed the speed of the physical interface on which it resides. There are restrictions on the changes that you can make to the rate limit of a termed VXC: * You can increase the speed to the maximum limit allowed. * You can reduce the speed to the committed term speed. You can change the speed as many times as you need during a term within the restrictions. ## VXC speed change example As an example, you create a VXC on a 12-month term with a rate limit of 5 Gbps. This is the committed term speed.\ The maximum limit allowed is calculated as 10 Gbps when you create the VXC. If you need to increase the speed, you can set it to a value between 5 Gbps and 10 Gbps. You cannot set it to more than 10 Gbps.\ When you want to decrease the speed, you cannot decrease it to less than 5 Gbps. ## Pricing The pricing rules for rate limit changes to a termed VXC are as follows: * The term discount is applied as a fixed monthly amount and does not change throughout the term length, regardless of any speed changes. * The fixed monthly discount amount is calculated off the percentage discount associated with the selected term length and original committed term speed. This means that if you increase the speed of a VXC on term, the term discount does not increase, but remains fixed to the original discounted amount based on the original committed term speed. * If you change the VXC speed, the service will be repriced at the current market rate. * If minimum term renewal is enabled, the contract will renew at the same market rate and term discount applied as when the speed change was ordered. ### Pricing example In this scenario, a 1 Gbps private VXC is created on a contract term. The table below shows the rack rate price, term discount, and total charged for each term duration. | 1 Gbps Metro Private VXC | No Min Term | 12 Months | 24 Months | 36 Months | | - | - | - | - | - | | Rack Rate Price | \$120 | \$120 | \$120 | \$120 | | Term Discount | \$0 | \$20 | \$25 | \$30 | | Total | \$120 | \$100 | \$95 | \$90 | If the speed of this service is increased to 10 Gbps on the 1st of the month, the following pricing will apply: | 1 Gbps Metro Private VXC updated to 10 Gbps | No Min Term | 12 Months | 24 Months | 36 Months | | - | - | - | - | - | | Rack Rate Price | \$240 | \$240 | \$240 | \$240 | | Term Discount | \$0 | \$20 | \$25 | \$30 | | Total | \$240 | \$220 | \$215 | \$210 | | Charge increase | \$120 ⬆ | \$120 ⬆ | \$120 ⬆ | \$120 ⬆ | Note the rack rate price rises with the speed increase, but the term discount remains the same. **Invoicing** You will see two line items on your invoice: * The service rack rate charge at the Month to Month/No Minimum Term rate. * The Fixed Monthly Term Discount. ## Canceling the VXC If the termed VXC is canceled, the early termination fee (ETF) is calculated based on the committed term speed, not the speed when the VXC is canceled. ## Considerations If you need greater flexibility in terms of increasing or decreasing the VXC speed, you might benefit from ordering a VXC on term at the minimum speed you require. This way, although the term discount will be lower, you will still get a term discount, with the added benefit of being able to adjust the speed as required. If you order the VXC on No Minimum Term, you will receive no discount at all. If you don’t anticipate the need to adjust the speed of the VXC regularly, you should order the VXC on term at the speed required to benefit from a higher term discount. ## Helpful references * [Connections Overview](/connections/overview) * [Creating a Private VXC](/connections/private-vxc) * [Quoting Service Cost](/finance/creating-estimates) * [VXC Pricing and Contract Terms](/finance/vxc-pricing) # Megaport Portal Dashboard Source: https://docs.megaport.com/dashboard/index This help topic describes how to use the Megaport Portal dashboard with the rotating globe feature. The Megaport Portal dashboard is an interactive experience that can show either a rotating globe or a flat projection. You can use the visualizations to see your Megaport defined network. You can also use it to add connections and services to your network. ## Dashboard views By default, you will see the interactive globe view. To change to the flat projection, click the flat map image on the right: This image shows the button that you click to get a flat map image. It has a monochrome image of the map of the world on it. For more information, see [Map controls on the right](#map-right). ## Maintenance and outage banner At the top of the page, a banner will be displayed to inform you about any future or ongoing maintenance or outages. If there are no maintenance or outages, the banner will not be displayed. The banner will only show events three days before the maintenance or outage is scheduled to occur. Select **View All** to see details about the maintenance or outage. Click **X** to close the banner. This image shows the maintenance and outage banner at the top of the page. ## Map controls There are control buttons on each side of the map, and a status bar along the bottom that summarizes your services. The buttons let you control what you see on the dashboard, and the status bar shows your service status at a glance. Hover the mouse over each control on the map to see its purpose. ### Move the globe To manipulate the globe view, click and drag on the globe. * On a standard mouse, left-click and drag * On an Apple magic mouse, click and drag * On a tablet, touch and drag ### Advanced globe view manipulation You can use commands to completely invert the globe. This is useful if you want to view your network in a certain way, or to take screenshots of parts of your network that can only be seen this way. **To invert the globe view to north at the bottom** * With a standard mouse, drag sideways while holding the right button or drag sideways while holding *ctrl* and left button * On a keyboard, click *shift* + left or right arrows **To restore the globe view to north at the top** * With a standard mouse, drag sideways while holding the right button or drag sideways while holding *ctrl* and left button * On the keyboard, click *shift* + up arrow. ### Map controls on the left The controls on the left side of the map help you control how much information you see. Use the location filter buttons at the top of the left controls to choose which locations appear on the map. | Control | Purpose | | :-: | - | | | Show all locations.
Displays all location types, including installed locations (Active and Deployment), [extended locations](#extended-locations), and locations where you have services. This is the default view. | | | Show installed locations.
Displays only installed Megaport locations (Active and Deployment status) where you can order services directly. Occupied locations (locations where you have services) and extended locations are hidden. | | | Show extended locations.
Displays only [extended locations](#extended-locations). Installed locations and locations where you have services are hidden. | | | Show locations where you have services.
Displays only locations where you have deployed services, along with connection lines between them. Empty locations (where you have no services) are hidden. | | | Filter empty locations.
See [Locations](/dashboard#locations) for more information about empty locations. | | | Map key.
This explains what the icons, colors, and links mean on the map, including the distinction between installed and extended locations. | | | Keyboard commands to control the map, including zoom and changing orientation. | ### Search The search function allows you to search the map for: * Any service type. For example, VXC. * A service name * A product ID * Megaport enabled locations but only if you do not have this turned off in your map settings * Any place name in the world ### Map controls on the right The controls on the right side of the map set the screen mode (normal or full-screen), the view (globe or flat map), and the level of zoom. | Control | Purpose | | :-: | - | | | Expand the map or globe to full screen.
The Megaport Portal header and options are hidden. To return to normal view, click **Exit full screen**. | | | Show the rotating globe view. | | | Show the flat map view. | | | Zoom in with large increments. | | | Zoom in with small increments. | | | Zoom out with small increments. | | | Zoom out with large increments. | ### Service status bar The service status bar is a full-width bar along the bottom of the map that summarizes the status of your configured services. Service status widgets From left to right, the bar begins with an **All Services** tile that aggregates the up and down totals across all service types. This is followed by a tile for each service type you have. Service types with no services are not shown. Each tile shows: * A circular status indicator divided into segments that represent the proportion of services that are up or down. * The total number of services for that service type. * A status summary showing the number of services that are down (for example, *3 down*), or *all up* when none are down. You can minimize the bar to a small pill that displays the total number of services. Click the pill to expand the bar again. Your browser remembers whether the bar was last minimized or expanded. If you do not have any services yet, the bar shows a **No services yet** message instead of tiles. ## Locations Each Megaport location is marked by a pin. The color of the pin indicates the location type and status: Locations | Pin | Status | | :-: | - | | | Blue for occupied.
An occupied location means that you have a Port or other network component at that location, or you have a connection that terminates on someone else's Port or network component at that location. | | | Red for installed empty.
An installed (empty) location means that Megaport hardware is available at that data center, but you do not currently have any services there. You can order services directly at these locations. | | | Black for extended empty.
An [extended location](#extended-locations) is a data center where Megaport hardware is not physically present, but services are available through a private connection from a nearby installed location. | Use the location filter buttons on the left side of the map to show or hide specific location types. For more information, see [Map controls on the left](#map-left). ### Location clusters When you click a cluster of either occupied or empty locations, it will zoom in to show the next level of services expanded to show each service or location. The color of the icon shows the status of the service: * Green for up and running * Red for provisioned but not running * Black for ports or connections that you do not own There is also a location icon, which you can click to create services and get location details. This image shows the individual services at this location. Each service is  represented as a colored disc with  a symbol on it representing the type of service. The colored discs are arranged in a circle. In this example, there are two red ports, two black ports, one green MVE, and a black disc representing the location. When you zoom out and the occupied locations are clustered, the number in the circle indicates the number of connections present in the clustered locations. The circle drawn around it shows the proportion of them that are up or down. The colors represent: * Green for up * Red for down This image shows a solid blue circle  containing a number two. The blue circle is surrounded by a green and red circle, which is two thirds red, and one third green. ### Location functions When a location is expanded, you can click the location icon to see a pop-up with buttons that allow you to create available services or connections at that location. This image shows the details for an expanded location. It says 'This location supports the following products:Ports - 10 Gbps, 100 Gbps, MCRs, MVEs. Cisco, VMware, Versa, Aruba, Fortinet, Palo Alto.' There are buttons along the bottom of the pop-up that say 'create port', 'create MCR', and 'create MVE'. For more information about creating services, see [Provision services](/getting-started#provision-services). ### Extended locations Extended locations are data centers in the same campus or metro area as an installed Megaport location. Megaport hardware is not physically present at extended locations, but you can access services through a private cross connect from an installed location. You can order this cross connect to the Megaport installed location from your Data Center Operator at the extended location. To view extended locations on the map, use the location filter buttons on the left side: * Click the **white pin** button to show all locations, including extended locations alongside installed and occupied locations. * Click the **black pin** button to show only extended locations and hide all other location types. Extended locations appear with black pins on the map. When you click an extended location pin, the pop-up shows: * The data center name, metro, and country * A banner indicating that the location is extended via private connection from installed sites * A list of installed (parent) sites that connect to the extended location To order services at an extended location, contact your Account Manager for assistance. Services are created from the installed (parent) locations, not directly at extended locations. For more information about location types, see [Understanding Locations](/enabled-locations). ## Component control When you have focus on a location, you can keep clicking down to an individual service. You can use the map interface to see details, create, and remove services or connections. Click a service or connection icon to expand it and see the details. ### See service details Click an icon to see the details for that service. This image shows the pop-up window that appears when you click an MVE icon. It shows the connection details. It tells you the name of the service, the vendor - Aruba in this case, the size of the service and where it is located. The image shows what the service is linked to using an heirarchical structure. This one is an Aruba MVE located in New York. It is linked to a Megaport Internet service, and a Megaport Marketplace service. ### Add network connections You can add network connections from the Megaport Portal dashboard. **To add network connections** 1. Click the Port or connection icon. You will see a pop-up window that allows you to add a service. This image hows the pop-up that appears when you click a port icon. It shows the port details, including the name, location and port speed. There is a button on the right side that allows you to add a connection. Along the bottom are an icon that allows you amend the details, a 'delete' button, and a 'lock' button. Underneath that block is a block that shows similar information for the connection, which in this case is an IX. There is no add connections button on the connection block. 2. Click **+Connection** to open the New Connection page. This image shows the page that appears when you click the add connections button. The standard New Connection page is shown, that allows you to choose a destination type from a row of icons. The icons are cloud, private vxc, Megaport Internet, internet exchange, Megaport Marketplace, and Enter service key.There is a cancel and a next button on the bottom of the page. For more information about creating services, see [Connections Overview](/connections/overview). The Megaport Portal saves where you were on the map if you head off to create or view services. When you finish that process, it takes you back to where you were. The Megaport Portal also saves your view of the map and will return you to the same zoom level so you see it as you last saw it. ### Update network connections You can use the service pop-up to change settings or delete the service. This image shows the icons you can use to update network connections. There is a cog icon that will take you to the details page, a delete button, and a lock button. Click the button to copy the service identifier. The service identifier is shown in a hash format. You can click the number to copy it to the clipboard for use elsewhere. ## Connections Connection lines can represent one or more connections between two locations. The color of the connection line indicates the status of the connection: * Green for up * Red for down This image shows the pop-up that appears when you hover over a connection icon on a one of the connection lines. It says 'This line represents 3 connections. Click to see details. When you click a connection icon, the pop-up displays the ends according to their relative geographic location. This means that the button on the left will take you to the Port at the geographical left and the same for the right side. This image shows the pop-up that appears when you click a connection icon. It shows the a-end and b-end and allows you to use buttons to edit the end details, delete and end, or lock an end. You can also copy the service identifier. There is a button that allows you to navigate to the end. Click the A-End or B-End ports to go directly to that Port. # Managing Connectivity with Megaport's APIs as a Service Provider Source: https://docs.megaport.com/deployment/csp-integration/index This help topic describes how an example service provider can integrate Megaport and automate the related tasks using Megaport APIs. Service providers can seamlessly integrate Megaport's functionality into their platform. They can control customer access to their on-ramps, such as Ports. Service providers can use a service key to manage customer access and secure connectivity to their on-ramps. They can set specific rate limits and segment customer traffic using VLANs. A service key is a code that is given by one Megaport account holder to another to connect two separate businesses together. Customers who have separate Megaport accounts can connect their Ports, MCRs, MVEs, and NAT Gateways to each other across the Megaport network, enabling business-to-business VXCs. Before allowing their customers to connect to an on-ramp using a service key, a service provider must first connect to the Megaport network. Once connected they must: * decide which of their connections should be used as on-ramps * map those on-ramp location to their user-defined regions or zones * consider the capacity and diversity zones for redundancy management This topic describes how you, as a service provider, can use Megaport APIs to reduce manual effort and enable faster provisioning of services. This will make it easier to sell private connectivity to your customers. ## Scenario QuantumGPU is a small service provider company, headquartered in Los Angeles, California, serving as a self-service, on-demand GPU-as-a-Service (GPUaaS) platform. Empowering businesses with GPU-accelerated computing across diverse geographic locations, QuantumGPU operates the following Ports: * 2 Ports in Los Angeles, USA (Equinix LA1 and CoreSite LA1) * 1 Port in New York, United States (Telehouse) * 1 Port in London, United Kingdom (Telehouse North) * 1 Port in Osaka, Japan (Equinix OS1) * 1 Port in Sydney, Australia (Global Switch Sydney West) Scenario showing the active ports the service provider owns QuantumGPU needs to control how their customers connect to the Ports and automate the process with APIs. QuantumGPU (service provider) plans to implement the following scenario: Scenario and workflow: A step-by-step process for connecting to a service provider's platform: Customer requests a connection to an on-ramp on the service provider’s platform. Service provider lists regions where Ports are available: USA, UK, Japan, Australia. Customer selects a region (USA). Service provider lists cities with live Ports in the USA: Los Angeles, New York. Service provider maps available Ports in Los Angeles to a region called US-West, allowing customers to connect to one of the available Ports in US-West. Service provider decides which on-ramp to offer to the customer, considering capacity/usage and diversity. Customer selects US-West and adds diversity. Service provider creates service keys to the selected Ports: Los Angeles 1 (blue zone) Los Angeles 2 (red zone) Customer creates connections using the service keys. ## Related terms Ensure that you are familiar with the following terminology used in this topic: **Megaport Cloud Router (MCR)** **Megaport Virtual Edge (MVE)** **On-ramp** An on-ramp is a direct, private connection to a service provider's available resources, for example, via a Megaport connection. To ensure fast and reliable connections, the service provider maps these resources to their regions or zones, sets rate limits, manages per-customer VLAN capacity, and so on. **Port** **Port diversity** **Service key** A service key is a code that is given by one Megaport account holder to another to connect two separate businesses together. Customers who have separate Megaport accounts can connect their Ports, MCRs, MVEs, and NAT Gateways to each other across the Megaport network, enabling business-to-business VXCs. **Virtual Cross Connect (VXC)** ## Authenticating as an API user Before you can use the Megaport APIs, you must authenticate with an access token. Before you can generate the access token, you must create an API key in the Megaport Portal. For more information, see [Creating an API Key](/api/api-key). The API key consists of a client ID and a client secret. You can use it to generate the access token that is used to authenticate as an API user. Access tokens are valid for 24 hours and must be regenerated after that time. Your integration with Megaport's API will need to take this into account. For more information, see [Generating an access token](/api/api-key#accesstoken). ## Managing on-ramps When your customer requests a connection to you, you will need to map the region or zone of the connection to a physical on-ramp to generate the service key. This section describes the API calls to map your users' service region or zone to your Megaport on-ramp. Megaport location and product identifiers are constant so this can be cached or stored safely without needing to refresh every time. These instructions describe how to do this using Postman and the Megaport API collection. For more information about the Postman setup, see [Megaport API Overview](/api). ### Prerequisites This section assumes that you: * have integrated Megaport into your platform. For more information, see [Integrating Megaport into your platform](/deployment/csp-integration#integrating). * are authenticated as an API user. For more information, see [Authenticating as an API user](/deployment/csp-integration#authenticating). ### Listing on-ramp locations This task describes how you can look up and list your available on-ramp locations (Port locations in our scenario) using the location identifiers. **To list on-ramp locations** This example uses Ports, but you can also use MCRs and MVEs. 1. After your customer requests to connect to an on-ramp, for example, a Port, use the **Get Product List API** with `"provisioningStatus": "LIVE"`to look up all the live Ports that you own. ```http theme={"theme":{"light":"github-light-high-contrast","dark":"github-dark-high-contrast"}} GET /v2/products?provisioningStatus=LIVE ``` 2. Filter and list the response using the **country** value. ```json {7} theme={"theme":{"light":"github-light-high-contrast","dark":"github-dark-high-contrast"}} "locationId": 60, "location": "CoreSite LA1", "locationDetail": { "name": "CoreSite LA1", "city": "Los Angeles", "metro": "Los Angeles", "country": "USA" ``` In our scenario, the list is as follows: * USA * UK * Japan * Australia 3. After your customer selects a region (USA), filter and list the response on the **metro** value. ```json {6} theme={"theme":{"light":"github-light-high-contrast","dark":"github-dark-high-contrast"}} "locationId": 60, "location": "CoreSite LA1", "locationDetail": { "name": "CoreSite LA1", "city": "Los Angeles", "metro": "Los Angeles", "country": "USA" ``` In our scenario, the list is as follows: * Los Angeles * New York 4. After your customer selects a region (US-West), filter and list the response on the **locationId** value. ```json {1} theme={"theme":{"light":"github-light-high-contrast","dark":"github-dark-high-contrast"}} "locationId": 60, "location": "CoreSite LA1", "locationDetail": { "name": "CoreSite LA1", "city": "Los Angeles", "metro": "Los Angeles", "country": "USA" ``` In our scenario, the list is as follows: * "locationId": **59** * "locationId": **60** ### Mapping an on-ramp location to a user-defined region or zone You can use the listed location identifiers, such as **locationId**, **metro**, or **country** and map them to your predefined custom region or zone names. By mapping the available on-ramps, like Los Angeles 1 (**"locationId": 59**) and Los Angeles 2 (**"locationId": 60**), to the predefined US-West region, your customers can select US-West on your platform and connect to an available on-ramp. ### Selecting an on-ramp You can use APIs to identify which on-ramp to connect to, for example, to connect to the Port with the least usage. You can consider factors such as the number of connections, capacity, or utilization. Additionally, you can consider factors like diversity zones to manage redundancy. Use the response of the filtered Ports to consider the Port attributes as follows: | Attribute | Consider | | - | - | | diversityZone | Check if the current location supports diversity.
For more information, see [Port Diversity](/connections/port-diversity). | | portSpeed | Check the available speed of the Port. | | rateLimit | The VXC rate limit cannot exceed the speed of the lowest speed Port.
For more information, see [Connections Overview](/connections/overview). | | associatedVxcs | Check if VXCs are associated with the Port and the allocated capacity. | | maxVxcSpeed | Check the maximum VXC speed available for the Port. | | vxcPermitted | Ensure that the **vxcPermitted** is true. If the **vxcPermitted** value is false, you cannot create a VXC to that Port. | After considering the selected Ports, you can display a Port that meets the required criteria, for example, a Port with the least usage. For more information, see [Megaport API Overview](/api). ## Managing connections By following best practices in managing the service keys and VLAN IDs, you can maintain organized and secure connections. ### Managing service keys Service keys allow your customers to establish connections to your specific on-ramps. Managing service keys involves creating, sharing, and monitoring the service keys. This process is shown and explained in more detail below: Process showing the service key workflow explained in more detail below After you select the on-ramp service, you can create a service key to the on-ramp. Creating the service key has no extra cost to you, regardless of whether your customer uses the key or not. Share the service key with your customer. Optionally, create a workflow for your customer, outlining the necessary steps and an indicative timeframe to use the received service key. As a prerequisite, your customer must have an account with Megaport and have an available Port. Using the service key, your customer can create a VXC and connect to the on-ramp based on the parameters you specified. Your customer is responsible for the VXC charges associated with the selected on-ramp location. Use the **GET List Service Keys** API to continually monitor and keep track of the status of your service keys. For example, check if a service key you created and sent to a customer has been used. After your customer uses the service key, it becomes obsolete, and the service key ID is not kept. This means that there is no connection between the service key and the service it activated. The service key is service-specific. To ensure redundancy and resilience in the event of failures or disruptions, we recommend that you create on-ramps located in different diversity zones. In this case, you must also create separate service keys for each on-ramp, for example: * 1 key for Los Angeles 1 in the blue diversity zone * 1 key for Los Angeles 2 in the red diversity zone You can create either a single-use or a multi-use service key. With a single-use service key, the customer you share the key with can request a single connection to a specific on-ramp. With a multi-use key, the customer with whom you share the key can request multiple connections. In such instances, the system automatically allocates the next available VLAN ID. ### Managing VLAN IDs For single-use service keys, specify a VLAN ID, which you can use to link customers to their respective VXCs. When you assign a VLAN ID to the service key, it indicates that the assigned VXC is dedicated to a specific customer. Each VXC is delivered as a separate VLAN on your on-ramp. This must be a unique VLAN ID on this on-ramp and can range from 2 to 4093. For single-use service keys, you can also specify **untagged**, which does not allocate a VLAN ID. For more information, see [Setting up Service Keys](/marketplace/service-keys). The image below shows that you assigned different VLAN IDs for each customer as follows: * VLAN ID 100 assigned to Customer 1 * VLAN ID 200 assigned to Customer 2 The VLAN IDs (100 and 200) assigned by you can differ from the VLAN IDs assigned by your customers (123 and 10), or the VLAN IDs assigned to other Port connections they have, such as those to cloud service providers like AWS, Oracle, or Azure (124, 125 and 20). Scenario showing that the VLAN IDs assigned by the service provider can differ from the VLAN IDs assigned by the customers For more information, see [Setting up Service Keys](/marketplace/service-keys) and [Creating a Service Key with the API](/api/api-create-servicekey). ## Summary This topic described how you can efficiently manage customer connections to your on-ramps. Using Megaport APIs, to look up Ports, select Ports based on capacity, diversity, and so on, you can automate the process, reducing manual effort and enabling rapid service provisioning. ### Summary of APIs used This table shows the process and the APIs used in this scenario: This example uses Ports, but the same process is used for MCRs and MVEs. | Action by the service provider’s customer | Action by the service provider | API requests and values used for filtering | Result | | - | - | - | - | | On the service provider’s platform, request a connection to an on-ramp. | List regions with live Ports, MCRs, or MVEs. | GET /v2/products?
provisioningStatus=LIVE

List `"country"` values. |
  • USA
  • UK
  • Japan
  • Australia
| | Select a region (USA). | List cities with live Ports, MCRs, or MVEs in the USA. | GET /v2/products?
provisioningStatus=LIVE
\&country=USA

List `"metro"` values. |
  • Los Angeles
  • New York
| | | List Ports in Los Angeles.

Map the available Ports for example, Los Angeles 1 ("locationId": 59) and Los Angeles 2 ("locationId": 60) to a region called US-West. Then, in your platform, your customers can connect to one of the available Ports in US-West.

Decide which on-ramp to offer to the customer. Consider capacity/usage and diversity. | GET /v2/products?
provisioningStatus=LIVE
\&country=USA\&metro=Los Angeles

List `"locationId"` values. |
  • Equinix LA1 (“locationId”: 59)
  • CoreSite LA1 (“locationId”: 60)
| | Select US-West and add diversity. | Create service keys to the selected Ports.

Send the service keys back to your customer. | POST /v2/service/key

Required value: `"productUid"` | 2 separate keys are created for:
  • Los Angeles 1 (blue zone)
  • Los Angeles 2 (red zone)
Example key:
"key": "106e38ae-eb59-415f-ac81-526a5299851d", | | Create connections with the service keys. | | | | ### Integrating Megaport into your platform For an example on how to integrate Megaport into your platform, see the demo project at [https://github.com/megaport/megaportgo](https://github.com/megaport/megaportgo). # Megaport Global Mesh WAN Overview Source: https://docs.megaport.com/deployment/global-mesh-wan/index This help topic describes what Megaport Global Mesh WAN is and provides detailed information on how to order it. Megaport Global Mesh WAN is a fully managed, cloud-ready Wide Area Network (WAN) service built for organizations with distributed locations. Unlike traditional setups that require a direct point-to-point connection between every site, Megaport Global Mesh WAN enables seamless and flexible connectivity among multiple data centers and sites. Megaport Global Mesh WAN provides a secure, scalable, and cost-effective solution for interconnecting offices, data centers, and cloud regions globally. It effectively eliminates the complexity of traditional WAN provisioning by seamlessly integrating your Megaport services. Leveraging its underlying Megaport mesh architecture, the service provides you with resilient, low-latency paths between all sites, alongside the flexibility to scale bandwidth on demand. Megaport Global Mesh WAN delivers predictable performance, reduces operational overhead, and offers an affordable model designed to meet stringent security and compliance requirements. ## Key benefits of Megaport Global Mesh WAN * **Global reach** -- Connect distributed sites, data centers, and clouds across multiple regions seamlessly. * **Resilient architecture** -- Megaport’s mesh design and red and blue zone diversity deployment ensure high availability, redundancy, and optimized traffic flows.\ For more information about diversity zones, see [Port Diversity](/connections/port-diversity), [MCR Diversity](/mcr/mcr-mve-diversity), and [MVE Diversity](/mve/mcr-mve-diversity). * **Scalable and elastic** -- Instantly adjust bandwidth and extend your network reach without complex re-engineering. * **Cost-effective** -- Achieve enterprise-grade connectivity at a fraction of the cost of traditional WAN solutions. * **Premium support** -- Access a dedicated Megaport Technical Account Manager (TAM) for proactive guidance and continuous support for your WAN environment. ## Types of Megaport Global Mesh WAN Megaport offers these types of Mesh WAN services: | **WAN Type** | **Deployment Strategy** | | - | - | | Domestic WAN | Required services are deployed in Megaport-enabled locations that are all located within the same country. This ensures localized, low-latency connectivity for national resources.

This service is currently available in Australia, Canada, and the USA.
| | Regional WAN | Required services are deployed in Megaport-enabled locations across multiple countries within the same region.

This service is available in Asia-Pacific (APAC), Europe, the Middle East, and Africa (EMEA), North America (NAM), and Latin America (LATAM) regions.
| | Trans Atlantic WAN | Required services are deployed on both sides of the Atlantic Ocean.

This service is available for routes between the US and Europe. | | Global WAN | Required services are deployed across numerous regions worldwide, including APAC, EMEA, NAM and LATAM. Your network infrastructure is unified into a single logical mesh network. | The following network diagram represents the fundamental concept of the Megaport Global Mesh WAN. The structure is consistently applied irrespective of the geographical scope of the four types of Global Mesh WAN. Megaport handles the entire mesh infrastructure, completely offloading your network management workload. You only need to establish connections to your chosen locations within the mesh via Virtual Cross Connects (VXCs). Global Mesh WAN ## Ordering Megaport Global Mesh WAN Below is a step-by-step workflow that describes how to order a Megaport Global Mesh WAN. 1. Contact your Megaport Account Manager or Solution Architect to discuss your requirements. We will use those requirements to design a network solution that meets your needs. 2. After you and Megaport agree on the proposed solution, your Megaport Account Manager will provide a Manual Service Order (MSO) form for your review and acceptance of pricing, terms, and conditions. 3. After you sign the MSO, your Megaport account team will configure the network as designed. If you need additional implementation support, tell your account team, and Megaport will introduce you to a Technical Account Manager (TAM) to discuss professional services. 4. You can then use these services through the Megaport Portal. ## Helpful references * [MCR Diversity](/mcr/mcr-mve-diversity) * [MVE Diversity](/mve/mcr-mve-diversity) * [Port Diversity](/connections/port-diversity) * [Understanding Locations](/enabled-locations) # Common Multicloud Connectivity Scenarios Source: https://docs.megaport.com/deployment/multicloud/index This help topic describes common design scenarios using Megaport for multicloud and hybrid cloud connectivity. This topic describes some common connectivity design scenarios using Megaport , , and . The scenarios range from a simple partially-protected network to an end-to-end highly available resilient network for and hybrid cloud. For more information about different multicloud scenarios and defining your connectivity requirements, see the [Design Scenarios for Multicloud -- Diversity and Design Principles blog](https://www.megaport.com/blog/design-scenarios-for-multicloud/). You can also download our Multicloud Network Blueprints Infopaper at [Multicloud Network Blueprints](https://www.megaport.com/pdf/megaport_multicloud_blueprints.pdf). To help you architect your multicloud solution, you can [download a Visio (VSDX) file](https://go.megaport.com/multicloud-vsdx-download.html) with these scenarios. Hybrid multicloud, non-redundant. Includes a single Port connecting to each CSP. | Property | Value | | - | - | | HA design | No | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 1 DC | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP * Customer (on-premises) network equipment supports IEEE 802.1ad (Q-in-Q) -- Specifically for Microsoft Azure If 802.1ad not supported, use Scenario 3 (MCR). | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 1 | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 4 (1 for each CSP) | Hybrid multicloud, non-redundant setup consisting of a single Port connecting to each CSP Hybrid multicloud, non-redundant. Includes dual Ports configured as a connecting to each CSP in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 1 DC | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP * Customer (on-premises) network equipment supports IEEE 802.1ad (Q-in-Q) -- Specifically for Microsoft Azure If 802.1ad not supported, use Scenario 3 (MCR). | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 (in LAG) | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 8 (2 for each CSP) | Dual Ports configured as a LAG connecting to each CSP in a HA configuration Hybrid cloud-to-cloud, non-redundant. Includes an MCR as a hub connecting a single Port in a DC with CSPs. | Property | Value | | - | - | | HA design | No | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 1 DC | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory) | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 1 | | Megaport Cloud Router (MCR) | Yes | 1 | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 5 (Including 1 for each CSP) | MCR as a hub connecting a single Port in a DC with CSPs Hybrid multicloud, redundant (single location). Includes a Port in each diversity zone connecting to each CSP in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP * Customer (on-premises) network equipment supports IEEE 802.1ad (Q-in-Q) -- Specifically for Azure If 802.1ad not supported, use MCR (Scenario 6). | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 (4 in a LAG) | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 8 (2 for each CSP) | Port in each diversity zone connecting to each CSP in a HA configuration Cloud-native, redundant. Includes dual MCRs as hubs that connect CSPs in a HA configuration without requiring on-premises infrastructure. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | No | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * None required | Megaport Technology | Required | How many? | | - | - | - | | Port | No | | | Megaport Cloud Router (MCR) | Yes | 2 | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 8 (2 for each CSP) | Dual MCRs as hubs that connect CSPs in a HA configuration without requiring on-premises infrastructure Hybrid cloud-to-cloud, redundant (single location). Includes dual MCRs as hubs that connect a DC with a Port in each diversity zone to CSPs in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes | | On-premises geographically close to CSPs | N/A | | Diverse regions | No | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory). | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 (4 in a LAG) | | Megaport Cloud Router (MCR) | Yes | 2 | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 10 (Including 2 for each CSP) | Dual MCRs as hubs that connect a DC with a Port in each diversity zone to CSPs in a HA configuration Hybrid multicloud, additional redundancy (multiple locations or regions). Includes a single Port in each DC connecting to CSPs in HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 2 DCs | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP * Customer (on-premises) network equipment supports IEEE 802.1ad (Q-in-Q) -- Specifically for Azure If 802.1ad not supported, use MCR (Scenario 8). | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 (4 in a LAG) | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 8 (2 for each CSP) | Single Port in each DC connecting to CSPs in HA configuration Hybrid cloud-to-cloud, additional redundancy (multiple locations or regions). Includes dual MCRs as hubs that connect DCs with Ports to CSPs in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory) | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 | | Megaport Cloud Router (MCR) | Yes | 2 | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 10 (2 for each CSP + 2 optional) | Dual MCRs as hubs that connect DCs with Ports to CSPs in a HA configuration Hybrid cloud-to-cloud, additional redundancy (multiple locations or regions). Includes dual MCRs as hubs that connect DCs with Ports in different diversity zones to CSPs in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 2 DCs | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory) | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 4 | | Megaport Cloud Router (MCR) | Yes | 2 | | Megaport Virtual Edge (MVE) | No | | | Virtual Cross Connect (VXC) | Yes | 12 (2 for each CSP) | Dual MCRs as hubs that connect DCs with Ports in different diversity zones to CSPs in a HA configuration Branch-to-multicloud, not connected to data center, non-redundant. Includes a single MVE connecting CSPs and branches. | Property | Value | | - | - | | HA design | No | | Multicloud | Yes | | On-premises data center (colocation) or office | No | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * None required | Megaport Technology | Required | How many? | | - | - | - | | Port | No | | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | Yes | 1 | | Virtual Cross Connect (VXC) | Yes | 4 (1 for each CSP) | Single MVE connecting CSPs and branches Branch-to-multicloud, not connected to data center, redundant. Includes dual MVEs connecting CSPs and branches in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | No | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * None required | Megaport Technology | Required | How many? | | - | - | - | | Port | No | | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | Yes | 2 | | Virtual Cross Connect (VXC) | Yes | 8 (2 for each CSP) | Dual MVEs connecting CSPs and branches in a HA configuration Branch-to-multicloud, connected to data center, non-redundant, dual underlay. Includes a single MVE connecting CSPs, branches, and a data center via a Port. | Property | Value | | - | - | | HA design | No | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 1 DC | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory) | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 1 | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | Yes | 1 | | Virtual Cross Connect (VXC) | Yes | 5 (Including 1 for each CSP) | Single MVE connecting CSPs, branches, and a data center via a Port Branch-to-multicloud, connected to data center, redundant, dual underlay. Includes dual MVEs connecting CSPs, branches, and data centers via Ports in a HA configuration. | Property | Value | | - | - | | HA design | Yes | | Multicloud | Yes | | On-premises data center (colocation) or office | Yes - 2 DCs | | On-premises geographically close to CSPs | N/A | | Diverse regions | Yes | **Prerequisites** * Customer (on-premises) network equipment supports LX optical 1 Gbps, LR optical 10 Gbps, or LR4 100 Gbps ports * Customer (on-premises) network equipment supports BGP (for better path selection, not mandatory) | Megaport Technology | Required | How many? | | - | - | - | | Port | Yes | 2 | | Megaport Cloud Router (MCR) | No | | | Megaport Virtual Edge (MVE) | Yes | 2 | | Virtual Cross Connect (VXC) | Yes | 10 (2 for each CSP + 2 optional) | Dual MVEs connecting CSPs, branches, and data centers via Ports in a HA configuration Legend # Megaport On-ramp as a Service Source: https://docs.megaport.com/deployment/onramp-as-a-service/index This help topic describes what Megaport On-ramp as a Service is and provides detailed information on how to order it. Megaport On-ramp as a Service (OaaS) is purpose-built for service providers to deliver private, dedicated connectivity to their end customers, helping them meet stringent security and compliance requirements. With Megaport OaaS, the entire process is fully automated. A virtual LAN () is created automatically, IP addresses are assigned, Border Gateway Protocol () peering details are generated, and traffic is secured end-to-end. Megaport OaaS eliminates the manual back-and-forth of service key exchanges and removes the need for additional development effort from service providers. By bypassing the risks of the public internet, Megaport OaaS provides a more secure, compliant, and reliable alternative for accessing mission-critical Software as a Service () applications, transporting sensitive data, and connecting to Security Service Edge (SSE) solutions, without the delays or complexity of manual provisioning. ## Who is it for? Megaport OaaS is suitable for a wide range of service providers, including SSE and Secure Access Service Edge () providers, storage providers, and any SaaS application providers delivering services to end customers. It is also well-suited for telco providers that need to deliver SSE, SASE, storage, and other SaaS services to their customers. The following network diagram shows how service providers integrate their services into the Megaport network fabric using Megaport OaaS. OaaS ## Key benefits of Megaport OaaS Megaport OaaS provides a platform for service providers to offer automated, secure, and private connectivity to cloud environments. Traditional connectivity methods often depend on expensive, fixed-capacity leased lines or expose traffic to the public internet, lacking the sophisticated automation found in hyperscaler private on-ramps. As a result, service providers’ customers are frequently pushed into manual, non-standardized connection processes. Megaport OaaS addresses this challenge by enabling service providers to deliver hyperscaler-level on-ramp automation without requiring internal development resources. The key benefits are summarized below. * **Private on-ramp** -- Provide private, direct connectivity to cloud environments. Eliminate the need for service providers to build and maintain their own on-ramp infrastructure or dedicate resources to connection automation. * **Automated provisioning** -- Facilitate the rapid, automated configuration of network elements. Automatically generate VLAN, IP address assignments, and Border BGP peering details within minutes, resulting in the delays and complexity of manual coordination or service key exchange processes. * **Secure transport** -- Offer a secure, dedicated path for data transport that bypasses the public internet. Enable secure transport without requiring the engineering of Virtual Private Network ()/() tunnels or the capital investment in dedicated private circuits. * **Global reach** – Extend network connectivity using the existing Megaport infrastructure. Allow service providers to establish connectivity in geographical regions where they lack a physical network footprint, providing a stable alternative to the public internet for global interconnection. ## Ordering Megaport OaaS Below is a step-by-step workflow that describes how to order a Megaport OaaS. 1. Contact your Megaport Account Manager or Solution Architect to discuss your requirements. We will use those requirements to design a network solution that meets your needs. 2. After you and Megaport agree on the proposed solution, your Megaport Account Manager will provide a Manual Service Order (MSO) form for your review and acceptance of pricing, terms, and conditions. 3. After you sign the MSO, Megaport will place the order and send the connectivity details to the service provider. ## Helpful references * [Introducing Megaport](/overview) * [Megaport Cloud Connectivity Overview](/cloud/megaport) * [Megaport Marketplace Overview](/marketplace/overview) * [Understanding Locations](/enabled-locations) # Modernizing Your MPLS Network with Megaport Solutions Source: https://docs.megaport.com/deployment/wan-replacement/index This help topic describes how to modernize your traditional WAN with Megaport solutions. Megaport enables a model for enterprise WAN connectivity that can replace services or reduce dependency on traditional providers. This topic describes options and considerations for modernizing your MPLS network. Although Megaport currently cannot replace all components of an MPLS network, Megaport can replace key parts and provide significant benefits with cost, flexibility, speed of deployment, and scalability. With the right plan, you can design a Megaport/MPLS hybrid solution and then gradually phase out more MPLS components as the Megaport product suite evolves. ## Megaport advantages The advantages of using Megaport's software-defined network (SDN) instead of MPLS include: * **Flexibility for optimal pricing** -- Megaport provides an extremely cost-effective solution compared to MPLS in most markets. At any time, you can add or delete services or adjust bandwidth for connections. This ensures you always have the right price, you can easily scale as your business grows, and you only pay for what you need. To take full advantage of the flexibility, you can implement tools to adjust connection speeds as required and get the full benefit of the elastic Megaport network. * **Free of long-term contracts** -- Megaport connections do not require long-term contracts, so you don’t have to predict traffic profiles for years at a time or get locked into a commitment for a specific topology. * **Speed of deployment** -- You can add and delete connections within minutes through the Megaport Portal or API. * **Consistent latency** -- Direct Layer 2 connections provide consistent latency and, in many cases, lower latency between locations, improving overall performance and increasing throughput. * **No risk** -- With no contracts and no long-term commitments to traffic profile estimates for the next several years, using Megaport lets you manage your network carefully and make adjustments as your business needs change. You are never locked into a long-term commitment or price. * **Dependability** -- Each Megaport data center has two or more diverse fiber connections into the Megaport global network, and each VXC is protected by all available fiber paths at the data center. Each connection automatically fails over to the next. ## Considerations There are some considerations when thinking about Megaport solutions with an MPLS network: * **Dealing with multiple providers and data center operators** -- With MPLS, you often commit to a contract with a single network provider. But the all-or-nothing MPLS relationship has real limitations that restrict you to a single network with a fixed, hardware-based configuration, reducing your growth options. While switching providers is not the easiest task, and adding Megaport introduces a new customer-provider relationship, you gain the advantage of Megaport’s Cloud Service Provider (CSP) agnostic approach to large-scale interconnection using dynamic connections. * **Challenging to connect Megaport to MPLS circuits** -- It can be difficult to terminate a connection from a Port to a carrier MPLS interface. MPLS providers have control of the router and are often resistant to adding Megaport details to the router and allowing access for Megaport traffic. Whether or not your MPLS provider will cooperate with Megaport needs to be a consideration in the design. * **Procuring the last mile** -- One of the biggest challenges in moving from MPLS to SDN is procuring, managing, and paying for the “last mile” connectivity. For more information, see [Next steps with SD-WAN](/deployment/wan-replacement#nextsteps). ## Current solutions Megaport supports hybrid networks for modular network design where you can easily deploy and manage Ports, Megaport Cloud Routers (MCR), and Virtual Cross Connects (VXCs) and integrate them with existing network infrastructure. ### Connectivity between data centers With Megaport, you can easily connect multiple sites and data centers and replace this part of your MPLS WAN. Megaport provides extensive connectivity between data centers around the globe and can reduce costs and improve performance for connections between data centers. This connectivity model builds on SDN principles and supports a more agile, on-demand approach instead of long-term, fixed-price contracts. By using Ports (physical ports in Megaport-enabled data centers) and VXCs, you can replace traditional point-to-point links and easily establish a secure, reliable connection between any of the global [Megaport enabled locations](https://megaport.com/megaport-enabled-locations). You can connect two or twenty data centers, set up a hub-and-spoke model, or create a fully meshed network. Data center connectivity For more information about Ports and VXCs: * [Creating a Port](/connections/creating-port) * [Creating a VXC](/connections/overview) ### Megaport Cloud Router (MCR) MCR is a managed virtual router service that establishes Layer 3 connectivity on the worldwide Megaport software-defined network (SDN). Incorporating MCR into your network design lets you manage routing decisions. MCRs don’t require a physical cross connect, letting you configure them close to your data sources to minimize latency and interconnect to Ports or CSPs using VXCs. MCR can be inserted as a hub to route traffic to multiple ports throughout the network, which optimizes traffic and reduces latency and bandwidth costs. #### MCRs with Cloud Service Providers MCR provides a smart way to integrate your cloud strategy with your existing MPLS network. As a virtual routing service, MCR can solve the complexities and costs that come with connecting your MPLS network to CSPs. You can add MCR as a node, or multiple nodes, on your existing MPLS network. MCR sits on top of the Megaport SDN at Layer 3 to provide a point-to-multipoint connection model and serve as a hub between CSPs. Your MPLS provider must support a single peer to MCR from their Provider Edge (PE) device. MCRs with CSPs For more information about MCR cloud configurations: * [Connecting an MPLS Network to the Public Cloud](https://megaport.com/blog/connecting-an-mpls-network-to-the-public-cloud) #### MCRs as regional hubs You can use MCR as the primary connection point for regional branch offices, CSPs, and data centers. In this hub-and-spoke design, MCR provides the hub and connects to spokes that are organized into regions based on proximity. The MCR hub connects your regional branches, CSPs, and data centers and VXCs connect the regional MCRs. MCR as a regional hub For more information about MCR: * [MCR Overview](/mcr) ## Next steps with SD-WAN The Megaport Virtual Edge (MVE) product supports replacing more MPLS functionality using Megaport to manage the connection between the customer branch and the data center. Customers no longer need to be in a multi-tenant data center to take advantage of Megaport’s interconnection capabilities. Megaport Internet gateway functionality enables internet-connected locations to access the Megaport SDN. For more information about MVE: * [MVE Overview](/mve) # Understanding Locations Source: https://docs.megaport.com/enabled-locations/index This help topic describes how to use the Megaport Enabled Locations page. Megaport’s global network infrastructure consists of carrier grade switching equipment hosted in data centers around the world. On the [Megaport Enabled Locations page](https://www.megaport.com/megaport-enabled-locations/), you can search for nearby Megaport Points of Presence (PoPs) where you can connect to the Megaport network. Enabled Locations map ## Using the Enabled Locations map There are two types of locations where you can connect to Megaport’s network: * **Installed** -- These locations contain Megaport networking hardware, and you can connect to any of them through the Megaport Portal. * **Extended** -- These locations share the same campus or metro area as an Installed Location. Megaport hardware is not located within the Extended Location facility, but you can access it through a private intra-campus or intra-metro cross connect. You can order this cross connect to the Megaport Installed location from your Data Center Operator at the Extended Location. Enabled Locations encompass both Installed and Extended Locations. **To find a PoP on the Enabled Locations map** 1. On the [Megaport Enabled Locations page](https://www.megaport.com/megaport-enabled-locations/), click Find My Location. Find My Location You can also click Locations and filter by provider, geographical location, or Megaport service availability. You can search for locations where you can connect to a Megaport Virtual Edge (MVE), a 100 G Port, or a Megaport Cloud Router (MCR). 2. Enter a street address to drop a pin on the map.\ The map zooms in on your specified address to include the pin and at least one Extended Location, if available. Zoomed in location A red pin represents an Installed Location, or Megaport PoP. A purple pin represents an Extended Location. When you zoom out, a black marker indicates a geographical area with a cluster of locations. The number on the black marker indicates how many red pins are located in the cluster. Click the black marker to zoom in on the locations. Black markers To connect to an extended location, click the purple pin and then click **Enquire about this location**. After you complete an inquiry form, a Megaport sales representative will reach out to you with information on setting up the physical cross connect. Extended location ## Viewing latency times The data used to calculate Megaport's network latency is collected from monitoring equipment in Megaport-enabled data centers worldwide, in 5-minute intervals. Monthly latency and packet delivery statistics are calculated by averaging all samples from that month. There are two ways to view latency times for a PoP: * On the [Megaport Enabled Locations page](https://www.megaport.com/megaport-enabled-locations/), click **View latency** on any Megaport PoP. * On the [Megaport Network Latency page](https://www.megaport.com/network-latency/), use location filters to search for a site. View latency link